G
e
t t
c
h
n
ic
a
l d
ta
,
in
s
tr
u
ti
o
n m
ls
r
v
e k
it
PANDA
Vacuum BoosterWV 0250 C, WV 0500 C
Instruction Manual
0870559556 | A0009_en-US | Original instructions
5/11/2022
Страница 1: ...Get technical data instruction manuals service kits PANDA Vacuum Booster WV 0250 C WV 0500 C Instruction Manual 0870559556 A0009_en US Original instructions 5 11 2022...
Страница 2: ...on 10 5 3 Filling Oil 11 6 Electrical Connection 13 6 1 Machine delivered without Control Box or Variable Speed Drive VSD 13 6 2 Wiring Diagram Three Phase Motor 14 7 Commissioning 16 7 1 Compression...
Страница 3: ...to state of the art methods Nevertheless residual risks may remain as described in the following chapters and in accordance with the chapter Intended Use 5 This instruction manual highlights potentia...
Страница 4: ...ion IN Suction connection MTB Motor terminal box OUT1 Discharge connection OUT2 Lateral discharge connection Optional MP Magnetic plug OFP Oil fill plug NP Nameplate OSG Oil sight glass BPV Bypass val...
Страница 5: ...eeable misuse outside the intended use of the machine Risk of injuries Risk of damages to the machine Risk of damages to the environment Make sure to follow all instructions described in this manual T...
Страница 6: ...ess gases with the machine component materials Risk of corrosion inside the compression chamber which can reduce performance and its lifetime Check if the process gases are compatible with those follo...
Страница 7: ...t the machine as shown NOTICE In case the machine is already filled with oil Tilting a machine that is already filled with oil can cause large quantities of oil to ingress into the cylinder Drain the...
Страница 8: ...ll apertures with adhesive tape or reuse provided caps If the machine is to be stored for more than 3 months Wrap the machine in a corrosion inhibiting film Store the machine indoors dry dust free and...
Страница 9: ...in any other way Make sure that the oil sight glass OSG remains easily visible Make sure that enough space remains for maintenance work Make sure that the machine is placed or mounted horizontally a...
Страница 10: ...tion NOTICE Ingress of foreign objects or liquids Risk of damage to the machine If the inlet gas contains dust or other foreign solid particles Install a suitable filter 5 micron or less upstream from...
Страница 11: ...ending on the specific configuration ordered other connection dimensions may apply 5 3 Filling Oil NOTICE Use of an inappropriate oil Risk of premature failure Loss of efficiency Only use an oil type...
Страница 12: ...When the oil filling is achieved Write down the oil change date on the sticker Last oil change __ __ ____ Oil type see nameplate Change interval see instruction manual If there is no sticker part no 0...
Страница 13: ...not be affected by electric or electro magnetic disturbance from the mains if necessary seek advice from Busch Make sure that the EMC of the machine is compliant with the requirements of your supply...
Страница 14: ...for the motor Busch recommends installing a D curve circuit breaker Connect the protective earth conductor Electrically connect the motor NOTICE Incorrect connection Risk of damage to the motor The wi...
Страница 15: ...tage motor with 9 pins low voltage Star connection multi voltage motor with 9 pins high voltage Double star connection multi voltage motor with 12 pins low voltage 4 4 4 Star connection multi voltage...
Страница 16: ...ning the machine must be filled with oil see Filling Oil 11 NOTICE Lubricating a dry running machine compression chamber Risk of damage to the machine Do not lubricate the compression chamber of the m...
Страница 17: ...flushing without using the barrier gas Beforehand a barrier gas must be connected according to the following illustration and recommendations 1 2 3 4 PANDA WV 0250 0500 C Description 1 Proces flow in...
Страница 18: ...nual PANDA WV 0250 0500 C_EN_en Close the gas supply Dry the machine of flushing fluid Do not operate the machine in normal operating conditions with the barrier gas opened It might affect the ultimat...
Страница 19: ...r to any action requiring touching the machine let the machine cool down first CAUTION Failing to properly maintain the machine Risk of injuries Risk of premature failure and loss of efficiency Mainte...
Страница 20: ...After the first 500 hours Change the oil of the gear and bearing housings both sides see Oil Change 21 Every 6 months Perform an oil inspection change it if the oil has changed its initial color see...
Страница 21: ...tion Manual PANDA WV 0250 0500 C_EN_en 21 36 8 4 Oil Change NOTICE Use of an inappropriate oil Risk of premature failure Loss of efficiency Only use an oil type which has previously been approved and...
Страница 22: ...aintenance 22 36 Instruction Manual PANDA WV 0250 0500 C_EN_en For oil type and oil capacity see Technical Data 29 and Oil 30 Fill up until the oiler OR is at least two thirds full with lip seals only...
Страница 23: ...When the oil filling is achieved Write down the oil change date on the sticker Last oil change __ __ ____ Oil type see nameplate Change interval see instruction manual If there is no sticker part no 0...
Страница 24: ...ny dismantling of the machine that goes beyond anything that is described in this manual should be done by Busch authorized technicians In case of the machine having conveyed gas that was contaminated...
Страница 25: ...let the machine cool down first Shut down the machine and lock against inadvertent start up Disconnect the power supply Vent the connected lines to atmospheric pressure Disconnect all connections If...
Страница 26: ...isk of premature failure Loss of efficiency The exclusive use of Busch genuine spare parts and consumables is recommended for the correct functioning of the machine and to validate the warranty There...
Страница 27: ...foreign matter or repair the machine contact Busch Equip the machine with a mesh screen at the suction connection The motor is defective Replace the motor The machine does not reach the usual pressure...
Страница 28: ...ses at the inlet too high Observe the permitted gas inlet temperature see Technical Data 29 Oil level too low Top up oil The backing pump is not correctly defined Contact Busch The oil is black Oil ch...
Страница 29: ...3000 3600 Sound pressure level 50Hz 60Hz dB A On request 59 63 Uncertainty KpA dB 3 Ambient temperature range C 5 40 Max gas inlet temperature C 200 P 10 hPa staging ratio of 4 Relative humidity at 3...
Страница 30: ...0250 0500 C_EN_en 14 Oil VSC 100 VSL 100 ISO VG 100 100 Part number 1 L packaging 0831 168 356 0831 122 573 Part number 5 L packaging 0831 168 357 0831 122 572 To know which oil has been filled in the...
Страница 31: ...ts and comply ies with the following designated standards that have been used to fulfill those provisions Standards Title of the Standard EN ISO 12100 2010 Safety of machinery Basic concepts general p...
Страница 32: ...Regulations 2021 and comply ies with the following designated standards that have been used to fulfill those provisions Standards Title of the Standard EN ISO 12100 2010 Safety of machinery Basic conc...
Страница 33: ...Instruction Manual PANDA WV 0250 0500 C_EN_en 33 36 Notes...
Страница 34: ...34 36 Instruction Manual PANDA WV 0250 0500 C_EN_en...
Страница 35: ...Instruction Manual PANDA WV 0250 0500 C_EN_en 35 36...
Страница 36: ...sence In every country highly competent local personnel delivers custom tailored support backed by a global network of expertise Wherever you are Whatever your business We are there for you Local repr...