8 | Maintenance
22 | 36
Instruction Manual MINK MM 1104-1142 BV_EN_en
8.5
Pressure Relief Lines Maintenance (Gas Tight Version
Only)
WARNING
Media potentially dangerous.
Risk of poisoning!
Risk of infection!
●
Wear appropriate personal protective equipment in case of high concentration of the medium in
the ambient atmosphere of the machine.
●
Check that pressure relief lines (PRL) are not clogged as described in the following illustrations.
1
2
Description
1
Unscrew nuts
2
Blow into the pipe
NOTICE
Pressurized air systems supply too high pressure.
Risk of damage to the machine!
●
Adjust the pressurized air to 0.2 bar(g) by means of a pressure regulator.
In case of clogged pressure relief lines (PRL):