Maintenance | 7
0870168409_MV0602B_O2_A0000_IM_en_MD
13 / 24
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
• Make sure that ear protection is being used.
• Make sure that the installation conditions (see
met.
• Switch on the machine.
• Make sure that the maximum permissible number of starts does not exceed 12
starts per hour. Those starts should be spread within the hour.
• Make sure that the operating conditions comply with the
.
As soon as the machine is operated under normal operating conditions:
• Measure the motor current and record it as reference for future maintenance
and troubleshooting work.
7
Maintenance
WARNING
Lack of oxygen regulation knowledge.
Risk of fire!
• Installation, commissioning and maintenance must only be carried out by qualified
personnel who are informed about the applicable safety regulations and trained in
the handling of oxygen.
• Accident prevention regulations or methods must imperatively be complied with.
Seek further information:
- European Industrial Gases Association “EIGA” www.eiga.eu (EIGA SAG NL
79/04).
- Berufsgenossenschaft Rohstoffe und chemische Industrie "BG RCI”
(Merkblatt M 034 Sauerstoff).
WARNING
Use of non-Busch genuine spare parts.
Risk of fire!
• Only use Busch spare parts approved by Busch and suitable for oxygen application.
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.