5 | Installation
10 / 24
0870168409_MV0602B_O2_A0000_IM_en_MD
5.3 Filling Oil
WARNING
Fill the machine with wrong oil type.
Risk of fire!
• Only use oil approved by Busch and suitable for oxygen application, see
.
At delivery, the machine is already filled with specific oil "Busch YLC 250 B" which is
suitable for oxygen application.
A lead seal is applied on the oil fill plug (OFP) and the oil drain plug (ODP) in order to
prevent wrong material from being filled in.
Lead seal must only be removed and applied by authorised and trained personnel,
seek advice from your Busch representative.
NOTICE
Remove lead seal without Busch approval.
Loss of Busch liability!
• Ask your Busch representative before filling or draining the oil.
NOTICE
Use of an inappropriate oil.
Risk of premature failure!
Loss of efficiency!
• Only use an oil type which has previously been approved and recommended by
Busch.
5.4 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
• Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
• The electrical installation must comply with applicable national and international
standards.
• Provide a lockable disconnect switch on the power line so that the machine is com-
pletely secured during maintenance tasks.
• Provide an overload protection according to EN 60204-1 for the motor.
• Busch recommends installing a D-curve circuit breaker.
• Make sure that the motor of the machine will not be affected by electric or electro-
magnetic disturbance from the mains; if necessary seek advice from Busch.
• Connect the protective earth conductor.
• Electrically connect the motor.