7 | Maintenance
18 / 28
0870159870_MV1202A_A0003_IM_en_MD
The oil level should stay constant over the lifetime of the oil. If the level does fall, this
indicates a leak and the machine requires repair.
7.5 Pressure Relief Lines Maintenance
(Gas Tight Version Only)
WARNING
Media potentially dangerous.
Risk of poisoning!
Risk of infection!
• Wear appropriate personal protective equipment in case of high concentration of
the medium in the ambient atmosphere of the machine.
• Check that pressure relief lines (PRL) are not clogged as described in the following
illustrations.
NOTICE
Pressurised air systems supply too high pressure.
Risk of damage to the machine!
• Adjust the pressurised air to 0.2 bar(g) by means of a pressure regulator.
In case of clogged pressure relief lines:
• Remove the clogging or have the machine repaired (contact Busch).