4 | Commissioning "Keypad"
10 / 56
0870166596_MV0040-0080C-D_PCI_A0004_IM_de_MD
4.6 Fault
When a fault appears, the display with the name of the fault starts to blink.
Active faults are indicated in the submenus F5.0 to F5.9. The memory of active faults
can store the maximum of 10 faults in the order of appearance.
The 10 latest faults are stored in the order of appearance in the fault history F6.0 to
F6.9.
Pressing the OK key on the selected fault shows the following details of the fault:
Code
Designation
Description
C
Code of the fault
Ident. No. of the fault
Id
Sub code of the fault
Some faults have a sub code for more de-
tailed identification.
0 = Fault without sub code
d
Day
Day according to the operating hours
counter
H
Hour
Hour according to the operating hours
counter
M
Minute
Minute according to the operating hours
counter
The fault remains active unless the fault will be reset by BACK/RESET key, by a reset
signal on terminal 10 of the control unit or disconnecting the pump from main power
supply for more than 10 seconds.
4.7 Controlling the Vacuum Pump with Keypad
• Switch to local control place with the LOC/REM key.
• Press the START key to start the vacuum pump.
• Press the STOP key to stop the vacuum pump.
• The speed of the vacuum pump can be changed in the group REF.