Remove the eye bolt (h, 615)
•
Remove the lid (424)
•
Remove the screw plugs of the pressure relief lines and
connect the pressurised air lines (
➔
illustration)
•
Apply 0.2 barg to the pressure relief lines (r)
•
Check that both pressure relief lines (r) pass the pressurised air
In case one or both pressure relief line(s) is/are clogged:
♦
Remove the vacuum pump from service and have it
repaired (Busch service)
♦
Reconnect the collecting line to the gas discharge (q) and
to the pressure relief lines
♦
Reinsert the screw plugs, remount the lid (424) and the
eyebolt (h, 615)
Every 20000 Operating Hours, At the Latest after
6 Years:
•
Have a major overhaul on the vacuum pump (Busch service)
Checking the Function of the
Measurement and Safety Instrumentation
(version with temperature monitoring only)
•
Make sure that the vacuum pump aspirates inert gases and
that there are no potentially explosive atmospheres in the
environment
•
Open the lid of the temperature measurement system (g)
•
Disconnect the white cable from pin 3, the first red cable from
pin 5 and the second red cable from pin 6
•
In order to simulate the resistance thermometer Pt100 set a
variable ohmic resistance to approx. 100
Ω
•
Connect the variable ohmic resistance with 3 identical cables
to the pins 3, 5 and 6 of the temperature transmitter as shown
in the sketch (the cable connected to pin 5 compensates the
cable resistance)
•
Switch on the vacuum pump
•
Increase the ohmic resistance to the resistance at shutdown
temperature according to the Equipment Documentation
Measurement and Safety Instrumentation (
➔
page 20)
•
Make sure that an alarm is released in the system control and
the vacuum pump is shut down automatically
•
Decrease the ohmic resistance to a value less than the
shutdown point
•
Make sure that the alarm persists
•
Make sure that the vacuum pump does not start self-acting
•
Switch on the vacuum pump again
•
Interrupt the ohmic resistance
•
Make sure that a fault indication is released in the system
control and the vacuum pump is shut down automatically
•
Reconnect the variable ohmic resistance
•
Switch on the vacuum pump again
•
Short circuit the variable ohmic resistance
•
Make sure that a fault indication is released in the system
control and the vacuum pump is shut down automatically
•
Remove the short circuit
•
Remove the variable ohmic resistance
CAUTION
Pressurised air supply systems supply a too high pressure.
Risk of damage to the vacuum pump.
Adjust the pressurised air to 0.2 barg by means of a pressure
regulator.
WARNING
Risk of electrical shock, risk of damage to equipment.
Electrical installation work must only be executed by
qualified personnel that knows and observes the following
regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100,
respectively,
- IEC-Report 664 or DIN VDE 0110,
- BGV A2 (VBG 4) or corresponding national accident
prevention regulation.
Содержание MINK MM 1102 BV
Страница 23: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 23 ...
Страница 24: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 24 0870141675 190709 ...
Страница 25: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 25 ...
Страница 26: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 26 0870141675 190709 ...
Страница 27: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 27 ...
Страница 28: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 28 0870141675 190709 ...
Страница 29: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 29 ...
Страница 30: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 30 0870141675 190709 ...
Страница 31: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 31 ...
Страница 32: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 32 0870141675 190709 ...
Страница 33: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 33 ...
Страница 34: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 34 0870141675 190709 ...
Страница 35: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 35 ...
Страница 36: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 36 0870141675 190709 ...
Страница 37: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 37 ...
Страница 38: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 38 0870141675 190709 ...
Страница 39: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 39 ...
Страница 40: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 40 0870141675 190709 ...
Страница 41: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 41 ...
Страница 42: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 42 0870141675 190709 ...
Страница 43: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 43 ...
Страница 45: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 45 ...
Страница 46: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 46 0870141675 190709 ...
Страница 47: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 47 ...
Страница 48: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 48 0870141675 190709 ...
Страница 49: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 49 ...
Страница 50: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 50 0870141675 190709 ...
Страница 51: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 51 ...
Страница 52: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight page 52 0870141675 190709 ...
Страница 53: ...MM 1104 1144 1102 1142 B V ATEX Version Gas Tight 0870141675 190709 page 53 ...