background image

EU Declaration of Conformity | 13

0870569132_SV_SD_DC1010-1040C_-0005_IM_en

23 / 24

13 EU Declaration of Conformity

This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the
Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.
When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery
(this can be the operating company, too) must conduct the conformity assessment process for the superordinate
machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.

The manufacturer

Busch Výroba CZ s.r.o.
Svárovská 620
CZ 460 01, Liberec 11

declares that the machine(s): 

SECO SV 1010-1040 C; SD 1010-1040 C; DC 0025-0040 C

has (have) been manufactured in accordance with the European Directives:

– ‘Machinery’ 2006/42/EC

– ‘Electromagnetic Compatibility’ 2014/30/EU

– ‘RoHS’ 2011/65/EU

and the following standards:

Standard

Title of the Standard

EN ISO 12100 : 2010

Safety of machinery - Basic concepts, general principles of design

EN ISO 13857 : 2019

Safety of machinery - Safety distances to prevent hazard zones being reached
by the upper and lower limbs

EN 1012-1 : 2010
EN 1012-2 : 1996 + A1 : 2009

Compressors and vacuum pumps - Safety requirements - Part 1 and Part 2

EN ISO 2151 : 2008

Acoustics - Noise test code for compressors and vacuum pumps - Engineering
method (grade 2)

IEC 60204-1 : 2016

Safety of machinery - Electrical equipment of machines - Part 1: General re-
quirements

IEC 61000-6-2 : 2016

Electromagnetic compatibility (EMC) - Generic standards. Immunity for indus-
trial environments

IEC 61000-6-4 : 2018

Electromagnetic compatibility (EMC) - Generic standards. Emission standard
for industrial environments

EN ISO 13849-1 : 2015 

(1)

Safety of machinery - Safety-related parts of control systems - Part 1: General
principles for design

(1)

 In case control systems are integrated.

Person authorised to compile the technical file:

Gerd Rohweder
Busch Dienste GmbH
Schauinslandstr. 1
DE-79689 Maulburg

Liberec, 16.04.2021

Michael Dostalek

General Manager

Содержание DC 0025 C

Страница 1: ...running Rotary Vane Vacuum Pumps SV 1010 C SV 1016 C SV 1025 C SV 1040 C SD 1010 C SD 1016 C SD 1025 C SD 1040 C DC 0025 C DC 0040 C 0870569132 0005_en Original instructions Modifications reserved 21...

Страница 2: ...7 5 1 Installation Conditions 7 5 2 Connecting Lines Pipes 8 5 2 1 Suction Connection 9 5 2 2 Discharge Connection 9 5 3 Electrical Connection 9 5 3 1 Wiring Diagram Single Phase Motor 10 5 3 2 Wiring...

Страница 3: ...s been designed and manufactured according to state of the art meth ods Nevertheless residual risks may remain This instruction manual highlights potential hazards where appropriate Safety notes and w...

Страница 4: ...PRV IN Suction connection MTB Motor terminal box OUT Discharge connection DA Directional arrow VA Vane NP Nameplate IIF Internal inlet filter VRV Vacuum regulating valve IDF Internal discharge filter...

Страница 5: ...essure see Technical Data 22 The machine is suitable for continuous operation Permitted environmental conditions see Technical Data 22 For heavy duty operation see Vacuum Regulating Valve 5 2 3 Standa...

Страница 6: ...stop for any reason The installation of non return valves is recommended if the lines of more than 5 meters are used 2 4 2 Inlet Filter The inlet filter protects the machine against dust and other sol...

Страница 7: ...ured to a base plate Remove the machine from the base plate 4 Storage Seal all apertures with adhesive tape or reuse provided caps If the machine is to be stored for more than 3 months Wrap the machin...

Страница 8: ...affected adversely in any other way Make sure that enough space remains for maintenance work Make sure that all provided covers guards hoods etc are mounted If the machine is installed at an altitude...

Страница 9: ...or throttle the discharge line 5 3 Electrical Connection DANGER Live wires Risk of electrical shock Electrical installation work must only be executed by qualified personnel Make sure that the power s...

Страница 10: ...ion can destroy the machine in a short time Prior to start up ensure that the machine is operated in the right direction Determine the intended direction of rotation with the arrow stuck on or cast Jo...

Страница 11: ...ne Risk of damage to hearing If persons are present in the vicinity of a non noise insulated machine over extended periods Make sure that ear protection is being used Make sure that the installation c...

Страница 12: ...nnected lines to atmospheric pressure If necessary Disconnect all connections 7 1 Maintenance Schedule The maintenance intervals depend very much on the individual operating conditions The intervals g...

Страница 13: ...Maintenance 7 0870569132_SV_SD_DC1010 1040C_ 0005_IM_en 13 24 7 2 Change Vanes and Internal Filters 1 2x 2 3 3x 1 2 3 only on SD and DC series only on DC series 5 mm hex key...

Страница 14: ...1025 1040 C and DC 0025 0040 C SV SD 1010 1016 C SV SD 1025 1040 C and DC 0025 0040 C H 33 mm H 27 mm H 27 mm H 33 mm Zirkon EK 60 SV 1025 1040 C H 33 mm SV 1025 1040 C H 33 mm Maintenance 3000h 1yea...

Страница 15: ...1040C_ 0005_IM_en 15 24 2 3x 3 1 1x flat gasket FG 1x internal discharge filter IDF on SD and DC series only 1x secondary internal inlet filter IIF2 on DC series only 1x internal inlet filter IIF 3x c...

Страница 16: ...Maintenance 16 24 0870569132_SV_SD_DC1010 1040C_ 0005_IM_en 7 3 Discharge Valve Maintenance SV version only 1 2 3 4 10 mm wrench 9 mm wrench 4 2 3 L 1 1x felt washer FW L 10 mm 10 mm wrench 9 mm wrenc...

Страница 17: ...s contaminated with foreign materi als which are dangerous to health Decontaminate the machine as much as possible and state the contamination status in a Declaration of Contamination Busch will only...

Страница 18: ...er FG Flat gasket FW Felt washer IDF Internal discharge filter IIF Internal inlet filter IIF2 Secondary internal inlet filter SR Sealing ring VA Vane Refer to the following table see Available Kits 19...

Страница 19: ...7 101 Service kit SV 1025 C With EK 60 vanes Includes 3x COW 1x FG 1x FW 1x IIF 7x VA 0994528979 Service kit SD 1025 C Includes 3x COW 1x FG 1x IDF 1x IIF 1x SR 7x VA 0994 567 102 Service kit DC 0025...

Страница 20: ...of electrical shock Electrical installation work must only be executed by qualified personnel CAUTION Hot surface Risk of burns Prior to any action requiring touching the machine let the machine cool...

Страница 21: ...nes or replace them The vanes VA are worn Replace the vanes The felt washer of the dis charge valve DV is partially clogged SV version only Dismantle the discharge valve and change the felt washer The...

Страница 22: ...h 10 12 16 19 25 30 40 48 Overpressure hPa mbar abs 1600 1600 2000 Nominal motor rating 50Hz 60Hz kW 0 37 0 37 0 55 0 55 0 9 0 9 1 25 1 25 Nominal motor speed 50Hz 60Hz min 1 1500 1800 Noise level EN...

Страница 23: ...5 EU and the following standards Standard Title of the Standard EN ISO 12100 2010 Safety of machinery Basic concepts general principles of design EN ISO 13857 2019 Safety of machinery Safety distances...

Страница 24: ...Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no Peru info busch com pe...

Отзывы: