Installation | 5
Instruction Manual COBRA NC 0400 B WCV_EN_en
13 | 44
5.2.2
Discharge Connection
Connection size(s):
At the machine discharge connection:
– DN63 ISO-K, DIN 28404
– DN80 PN6, EN 1092-1
At the silencer (SI) discharge connection (two optional versions available):
– DN80 PN16 + ANSI/ASME B16.5-3” class 150 lbs
– R3
●
Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurised air source.
●
Make sure that the counter pressure (also termed back pressure) at the discharge connection
(OUT) does not exceed the maximum allowable discharge pressure, see
5.2.3
Cooling Water Connection
CWI
CWO PHE
Description
CWI
Cooling water inlet
CWO
Cooling water outlet
PHE
Plate heat exchanger
●
Connect the cooling water connections (CWI / CWO) to the water supply.
Connection size:
– G1/2, ISO 228-1 (CWI / CWO)
●
Make sure that the cooling water complies with the following requirements:
Supply capacity
l/min
4 ... 6
Water pressure
bar
1 ... 6
Supply temperature
°C
+5 ... +30
Required pressure differential across supply
and return
bar
≥
1