5 | Installation
12 | 40
Instruction Manual COBRA NX 0450-0650 A WCV_EN_en
5.2.2
Discharge Connection
1
Description
1
Discharge variants (without silencer)
NOTICE
Discharge gas flow obstructed.
Risk of damage to the machine!
●
Make sure that the discharged gas will flow without obstruction. Do not shut off or throttle the
discharge line or use it as a pressurized air source.
Connection size(s):
At the machine discharge connection:
– G2 for NX 0450 A, horizontal (orientable 180°)
– G3 for NX 0650 A, horizontal (orientable 180°)
– DN63 ISO-K, DIN 28404 for NX 0450 A, vertical (without discharge elbow)
– ISO DN100, DIN 28404 for NX 0650 A, vertical (without discharge elbow)
At the silencer (SI) discharge connection (Optional):
– G2 for NX 0450 A, G3 for NX 0650 A, horizontal
●
Make sure that the counter pressure (also termed back pressure) at the discharge connection
(OUT) does not exceed the maximum allowable discharge pressure, see Technical Data.