Maintenance | 7
0870219588_NS0600C_WCV_Ex_-0000_IM_en
31 / 40
For cooling liquid type and cooling liquid capacity see
and
.
4
1
2
Coolingliquid
Zitr
ec M-25
3
Fill up to the top of the vent orifice
7.6 Calibration Procedure of the Electrical Devices
7.6.1 Procedure A
• Remove the resistance thermometer from the machine.
• Check it with a calibrated oven or send it to an approved laboratory for inspection.
• Reassemble the resistance thermometer on the machine.
7.6.2 Procedure C
• Remove the pressure transmitter from the machine.
• Compare it with another calibrated pressure transmitter or send it to an approved
laboratory for inspection.
• Reassemble the pressure transmitter on the machine.
7.6.3 Procedure E
• Check that the flow switch changes state when the ball of the flowmeter is passing.
It is not necessary to disassemble the flowmeter or its switch.