13 | Technical Data
38 | 44
Instruction Manual COBRA NX 0950 A WCV_EN_en
13
Technical Data
NX 0950 A WCV
Pumping speed (72Hz)
m³/h
950
ACFM
560
Ultimate pressure
(without gas ballast)
hPa (mbar) abs.
≤
0.01
TORR
≤
0.0075
Ultimate pressure
(with gas ballast)
hPa (mbar) abs.
≤
0.05
TORR
≤
0.0375
Nominal motor rating
kW
18.5
HP
25
Nominal motor speed (72Hz)
min
-1
4320
RPM
4320
Max. intensity
A
35
Circuit breaker (MCCB)
A
C-50 (SCCR 10kA @ 400V)
Noise level (EN ISO 2151)
dB(A)
≤
75
Ambient temperature range
°C
5 … 40
°F
41 … 104
Max. allowable counter pressure at
the discharge
hPa (mbar) rel.
200
TORR
150
Max. allowable gas inlet tempera-
ture according to the inlet pres-
sure
°C
≤
50 hPa (mbar) abs.
►
200
>
50 hPa (mbar) abs.
►
70
°F
≤
37.5 Torr
►
392
>
37.5 Torr
►
158
Relative humidity
at 30°C
90%
at 86°F
90%
Ambient pressure
Atmospheric pressure
Cooling water requirements
See Cooling Water Connection [
Oil capacity - motor side
L
1
qts.
1.05
Oil capacity - suction side
L
1
qts.
1.05
Weight approx.
Kg
900
Lbs.
2000