NOTE

: VCI is the abbreviation for “volatile corrosion inhibitor”. The

VCI molecule is an organic corrosion inhibitor in the vapour phase.
Integrated in various carriers such as film, cardboard, paper, foam,
liquid and powder, it protects parts against corrosion as a result of its
action in vapour phase. However, VCI packaging can attack plastic
surfaces and surfaces of other elastomers. If in doubt, please contact
your nearest distributor. VCI packaging provides several years of
protection against corrosion, even under harshest conditions: overseas
shipment, extended storage before use.

l

Wrap the vacuum pump in VCI film

l

Store the vacuum pump

if possible in its original packaging,

indoors,

dry,

in a dust free and

vibration free area

Starting-up of the vacuum pump after storage

l

Please ensure that all protective agents such as gaskets, plugs or
adhesive tapes that were used for the protection of the pump, are
removed.

l

Commission the vacuum pump as described in chapter “Installa-
tion and Commissioning”

Installation and
Commissioning

Installation prerequisites

CAUTION

If the installation prerequisites are not followed, especially in case of
insufficient cooling or a disregard of the alarm values of the surveil-
lance devices:

Risk of damage or destruction of the vacuum pump and its compo-
nents!

Risk of injury to people!

The installation prerequisites must be followed.

l

Please ensure that the integration of the vacuum pump in its new
environment is compliant with the safety requirements of the Ma-
chine Directive 2006/42/EC and the Directive 99/92/EC for explo-
sive zones (concerning the responsibility of the system’s
manufacturer into which the vacuum pump is to be incorporated,
please also refer to the note in the EU-Declaration of Conformity).

WARNING

Local regulations regarding the motors and electric control ele-
ments must be observed when installing the pump in potentially
explosive environments. Before start-up, make sure that all safety
measures have been followed.

Local installation

l

During installation, make sure that the surroundings of the vacuum
pump are not potentially explosive

l

Make sure that the following ambient conditions are adhered to:

Standard starting with ambient temperature: -20 ... 40 °C:

Possible starting with ambient temperature: -20 ... 60 °C only with
a motor and a coupling adapted to those temperatures (option on
demand):

u

Make sure the oil type corresponds to the ambient conditions,
see “Oil type”

Ambient pressure: atmospheric

Humidity range: 20 to. 95%

Altitude: up to 1000 m

l

Make sure that the cooling liquid fulfills the following require-
ments:

Temperature: 10 - 25 °C

Pressure of the network: max. 6 bar (relative) - min. 1,5 bar

l

Make sure that the cooling liquid is neutral and clean

l

Make sure that the cooling liquid outlet is unpressurised

l

Make sure that the environment conditions correspond to the pro-
tection class of the motor (according to motor nameplate)

l

Make sure that the vacuum pump is placed on or fastened to a ho-
rizontal surface

l

Make sure that the vacuum pump and chassis assembly are level to
within 1° in all directions when measured from a suitable machined
pump surface e.g. the pump inlet

l

Prior to final fixation of the pump, ensure that the chassis and fixa-
tion positions are all in contact with the installation base/ base
frame; use suitable shim material where necessary.
The maximum permissible space between the pump chassis/ fixa-
tion positions and installation base/ base frame = 0.05 mm

l

Make sure that the vacuum pump cannot inadvertently or intentio-
nally be used as a support for heavy objects

l

Make sure that the vacuum pump cannot be hit by falling objects

l

Make sure that the vacuum pump is at least 1 m away from any
wall

l

Make sure that the vacuum pump is easily accessible and that the
selected installation site fulfills the requirements for assembly/
dismantling

l

Make sure that no temperature-sensitive part (such as plastic,
wood, cardboard, paper, electronic parts) come into direct contact
with the hot surfaces of the vacuum pump

l

Make sure that the installation site or assembly area is ventilated in
such a way that adequate cooling of the vacuum pump is assured

CAUTION

During operation the surface of the vacuum pump may exceed tem-
peratures of 70° C.

Risk of burns!

l

Make sure that the vacuum pump cannot be touched inadvertently
during operation, provide a guard if necessary

l

Make sure that the oil sight glasses (OSG) will remain easily acces-
sible

If the oil change is meant to be performed on site:

u

Make sure that the oil drain ball valves as well as the oil filler
plugs, are easily accessible.

Suction connection

l

Make sure that the protection that prevents the ingress of foreign
matter during transport, has been removed before connecting up
the vacuum pump to the piping.

CAUTION

Do not put hands into the inlet aperture.

Risk of body damage!

CAUTION

The ingress of foreign objects or liquids can destroy the vacuum
pump.

Installation and Commissioning

Page 7

Содержание COBRA AC 1000 F

Страница 1: ...e Instructions Screw Vacuum Pumps COBRA AC 1000 F VR Vapour Recovery ATEX version II 2G i o IIB T4 X Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland 0870561056 180809 Original instructi...

Страница 2: ...First start up of the system 13 Switching off the system 13 Re start procedure following an Emergency Shut Down of the system 14 Maintenance 14 General information 14 Maintenance program 15 Weekly 15...

Страница 3: ...g liquid inlet connection CLO Cooling liquid outlet connection OFP Oil filler plug OSG Oil sight glass ODV Oil drain ball valve MP Magnetic plug DV1 Ventilation G1 4 DV2 Aeration valve CLD Cooling liq...

Страница 4: ...g liquid injection in the cylinder The COBRA vacuum pumps the principle of screw pumps Two parallel screws RT rotate in opposite directions in the pump body Entering gases are trapped between the pitc...

Страница 5: ...l accordingly Local regulations regarding the motors and electric control elements must be observed when installing the pump in potentially explosive environments The maintenance instructions must be...

Страница 6: ...careful packing Check the packaging for transport damage when the goods arrive The pump can withstand temperatures between 25 C and 55 C during transport Transportation of packaged pump Packed on a p...

Страница 7: ...pe corresponds to the ambient conditions see Oil type Ambient pressure atmospheric Humidity range 20 to 95 Altitude up to 1000 m l Make sure that the cooling liquid fulfills the following require ment...

Страница 8: ...scharge lines the line cross section should be larger than the exhaust flange in order to prevent a drop in the performance of the vacuum pump If you have any doubts contact your Busch representative...

Страница 9: ...or PSA 0301 The sensor must be connected in such a way that the vacuum pump stops when the counter pressure reaches the value prescribed in the COBRA ATEX catalogue Technical data of the standard prod...

Страница 10: ...meter FSA 0502 The contact flow meter must be connected in such a way that the vacuum pump stops when the flow drops below 2 l min It is possible to run the vacuum pump with an injection liquid flow o...

Страница 11: ...talogue If the unit motor coupling hub is already fitted u Move the coupling hubs on the shafts in order to reach value E see COBRA ATEX catalogue l Lock the coupling hubs by tightening the set screws...

Страница 12: ...t the cooling liquid inlet CLI and outlet CLO connections l Open the cooling liquid supply l Adjust the cooling liquid flow to 12 l min Connection of the injection liquid into the cylinder INJ NOTE Ma...

Страница 13: ...e that the Installation Prerequisites are complied with and will remain so and ensure that adequate cooling is guaranteed If the pump is shut down for a longer period of time CAUTION If there is a ris...

Страница 14: ...ations given below WARNING The inside of the vacuum pump must regularly be checked for de posits and be cleaned as and when necessary for example by pur ging the pump Deposits can cause friction and s...

Страница 15: ...eaks have the vacuum pump repaired Busch service l Check the vacuum pump for cooling liquid leaks in case of leaks have the vacuum pump repaired Busch service In case of operation in a dusty environme...

Страница 16: ...ler plugs OFP l Top up with oil l Make sure that the oil level is on MAX mark of the oil sight glass l Make sure that the seal of the oil filler plug are not damaged and replace plug if necessary l Re...

Страница 17: ...ing liquid in compliance with applicable re gulations Checking the current consumption l Check the current of the motor An increased current indicates a fault see Troubleshooting Checking the motor ho...

Страница 18: ...es must be disposed of separately in compliance with applicable environmental regulations When the vacuum pump comes to the end of its life it must be decontaminated CAUTION Only authorised personnel...

Страница 19: ...artial clogging in the suction discharge or pressure line Remove the clogging Long suction discharge or pressure line with too small diameter Use larger diameter Internal parts worn or damaged Repair...

Страница 20: ...ral weeks or months Let the vacuum pump run warm with inlet closed Oil viscosity is too high for the ambient tempe rature Use oil with a better viscosity class Improper oil quantity unsuitable oil typ...

Страница 21: ...ge intervals are too long The oil was overheated Drain oil Fill in new oil see Maintenance In case the oil life is too short use oil with better heat resistance or retrofit cooling Cooling liquid flow...

Страница 22: ...1 0486000766 510 O ring 2 0486511445 511 O ring 1 0486000645 512 O ring 2 0486000526 513 O ring 2 0486000636 514 O ring 2 0486000538 515 Shaft seal 1 0487553116 516 Seal 2 0486511080 732 Flat seal 1 0...

Страница 23: ...ellus S2 V 68 High Performance hydraulic oil viscosity class ISO HC 68 20 60 C TOTAL AZOLLA ZS 68 viscosity class ISO VG 68 Oil quantity The quantity of oil specified in the following table is of info...

Страница 24: ...l motor speed 50 Hz 60 Hz min 1 min 1 3000 3600 Noise level EN ISO 2151 50 Hz 60 Hz dB A dB A 83 85 Ambient temperature C 20 40 Ambient temperature high temperature version refer to the pump nameplate...

Страница 25: ...tances to prevent hazard zones being reached by the upper and lower limbs EN 1012 1 2010 EN 1012 2 1996 A1 2009 Compressors and vacuum pumps Safety requirements Part 1 and 2 EN ISO 2151 2008 Acoustics...

Страница 26: ...Note...

Страница 27: ...Note...

Страница 28: ...Majang myun Icheon si Gyunggi do 467 813 Republic of Korea Phone 82 31 645 2700 Fax 82 31 631 2898 e mail busch busch co kr Malaysia Busch Malaysia Sdn Bhd 4 6 Jalan Taboh 33 22 Seksyen 33 Shah Alam T...

Отзывы: