Operating Instructions 

Busch-Wächter

®

 

 

 

Pos: 2 /#Neustruktur#/Online-Dokumentation (+KNX)/Titelblätter/Waechter/Titelblatt - 6847-6867-MasterLINE -- BJE @ 24\mod_1338458140180_15.docx @ 214600 @  @ 1 

 

 
6847   220 MasterLINE 
6867   280 MasterLINE 

 
 

 

 

 

 

 

 
 

 

=== Ende der Liste für Textmarke Cover === 

 

Содержание 6847 220 MasterLINE

Страница 1: ...nstructions Busch Wächter Pos 2 Neustruktur Online Dokumentation KNX Titelblätter Waechter Titelblatt 6847 6867 MasterLINE BJE 24 mod_1338458140180_15 docx 214600 1 6847 220 MasterLINE 6867 280 MasterLINE Ende der Liste für Textmarke Cover ...

Страница 2: ...g methods 8 6 2 1 1 Wall mounting 8 6 2 1 2 Wall mounting with gradient 9 6 2 1 3 Ceiling mounting 9 6 2 2 Corner mounting 10 6 2 3 Installation sites 10 6 2 4 Preparing the installation 11 6 2 5 Mounting steps 12 6 3 Electrical connection 13 6 3 1 Standard connection 13 6 3 2 Standard connection with extension unit push button 13 6 3 3 Standard connection with RC suppressor 6899 and relay 13 7 Co...

Страница 3: ...hriften Für alle Dokumente 1 Ebene U Z Umwelt 18 mod_1302614158967_15 docx 103383 1 1 3 Environment Pos 10 2 Neustruktur Online Dokumentation KNX Sicherheitshinweise und Hinweise Für alle Dokumente Hinweise Hinweis Umwelt Hinweis Elektrogeräte 18 mod_1302763973434_15 docx 103500 1 Consider the protection of the environment Used electric and electronic devices must not be disposed of with domestic ...

Страница 4: ...ment detectors which switch loads via the KNX bus when sources of heat move within its detection range Busch Watchdog is not an intrusion or attack alarm Pos 14 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokumente 2 Ebene A F Funktions und Ausstattungsmerkmale 23 mod_1336557630140_15 docx 209136 2 1 4 3 Features of function and equipment Pos 15 Neustruktur Online Dokumentation KNX...

Страница 5: ...ector offers optimum surveillance if mounted to the wall at a maximum height of 2 5 m Pos 20 Neustruktur Online Dokumentation KNX Überschriften Für alle Dokumente 3 Ebene A F Erfassungsbereiche Reduzierung 29 mod_1347612043430_15 docx 233618 22222 1 4 4 2 Limitation of the detection range Pos 21 DinA4 Anleitungen Online Inhalt Waechter Erfassungsbereiche Einengung 220 280 28 mod_1347516663330_15 d...

Страница 6: ...300 lux Switch off delay 10 seconds 30 minutes Short time pulse Pulse duration 1 second Pause time 9 seconds Pause time with continuous light presence simulation 55 seconds Coverage if mounted 2 5 m high Maximum of 16 m Operating temperature 25 C 55 C Protection type IP 55 Pos 25 Neustruktur Online Dokumentation KNX Sicherheitshinweise und Hinweise Für alle Dokumente Hinweise Allgemein Hinweis Ans...

Страница 7: ...docx 209179 112 1 6 1 Requirements for the electrician Warning Electric voltage Install the device only if you have the necessary electrical engineering knowledge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements f...

Страница 8: ...power supply prior to installation and or disassembly Pos 33 Neustruktur Online Dokumentation KNX Montage Waechter Montage 6847 6867_220 280 MasterLINE 24 mod_1338446781648_15 docx 214481 222222224223333 1 Caution Risk of damaging the device The lens of the device is sensitive and can easily sustain damage Do not press on the lens when setting the device 6 2 1 Mounting methods There are four metho...

Страница 9: ...th gradient Wall mounting with gradient is recommended on a building situated on a hill or with a gradient This allows the detection ranged to be used effectively 6 2 1 3 Ceiling mounting Fig 4 Ceiling mounting There are two options for ceiling mounting 1 From the bottom for a wider detection range 2 With a corner adapter which allows the device to be ideally positioned ...

Страница 10: ...s available via the link http www busch jaeger katalog de index php in the Busch Watchdog category under accessories 6 2 3 Installation sites Fig 6 Installation sites Ceiling mounting in narrow rooms is not recommended The mounting height of the device should be between 1 7 m and 2 5 m The distance between light and movement detector should be at least 1 5 m For optimum detection of persons the ap...

Страница 11: ...teps Fig 7 Preparing the installation 1 Remove the locking screw 1 if installed 2 Press in the clamps 2 5 on the sides of the housing with a suitable tool 3 Carefully remove the front of the device Fig 8 Opening the water drain Depending on where the device is installed the water drain may have to be opened To do this pierce the plastic membrane on the bottom of the device The installation is prep...

Страница 12: ...he bolting dimensions of the base may be compatible with existing bores on older versions of the Busch Watchdog Latch the upper part of the device onto the base 3 To protect the device against unauthorized opening the enclosed screw can be used on the bottom of the device To protect the device against unauthorized opening screw the enclosed screw into the bottom of the device Pos 34 Neustruktur On...

Страница 13: ...mod_1338459376540_15 docx 214643 11133 1 6 3 1 Standard connection Fig 10 Universal relay insert 6 3 2 Standard connection with extension unit push button Fig 11 Universal relay insert with extension unit push button Note For more information see chapter Extension unit operation 8 4 on page 17 6 3 3 Standard connection with RC suppressor 6899 and relay Fig 12 Universal relay insert with RC suppres...

Страница 14: ...4 mod_1338448339667_15 docx 214542 3221233 1 7 1 Setting limiting the coverage and the detection range Caution Risk of damaging the device The lens of the device is sensitive and can easily sustain damage Do not press on the lens when setting the device Use the following steps to set the coverage and the detection range Fig 13 Adjusting the lateral detection range 1 Adjust the lateral detection ra...

Страница 15: ... S The device is now in test mode for 10 minutes daytime operation switch off delay 2 sec In addition each detection is indicated by the status LED flashing quickly The device then switches back to standard operating mode 2 To carry out an additional activation test set the selector switch back to position T S or interrupt the operating voltage supply for more than 15 seconds The device is now in ...

Страница 16: ...n continuous light set only possible with remote control Flashes fast detection in test mode Flashes 3 times detection in standard and normal operation Flickers incoming IR signals remote control 2 Lens 3 Trim potentiometer for switch off delay short time pulse 4 Trim potentiometer for brightness value test standard operation 5 Screw for dismantling safety 8 2 Standard operation Fig 18 Standard op...

Страница 17: ...tur Online Dokumentation KNX Nebenstellenbetreib Waechter Nebenstellenbetrieb 68476867 220 280 MasterLINE 28 mod_1347514657878_15 docx 233191 1111 1 8 4 1 Operation with extension unit push button Aside from the movement detector being triggered by the infrared radiation in the detection range manual operation is possible via an extension unit push button For example when an exit is not within the...

Страница 18: ...least 1 second 2 The current brightness is set as switch on brightness Press the button for at least 1 second 3 Deactivation of presence simulation 4 Presence simulation activation Continuous light between twilight and 22 30 p m CET or 23 30 CEST Followed by movement detection 5 Light deactivation for 4 hours No detection of movement 6 Light activation for 4 hours No detection of movement 7 Resett...

Страница 19: ...ower on the Busch Watchdog The Busch Watchdog must be de energized beforehand for at least 30 seconds The remote control will then automatically connect itself to the Busch Watchdog and the Busch Watchdog will flash if the reception is correct Repeat these steps to program a maximum of 9 additional remote controls 9 4 Battery change of remote control Fig 24 Changing the battery 1 Pull the battery ...

Страница 20: ...Notice We reserve the right to at all times make technical changes as well as changes to the contents of this document without prior notice The detailed specifications agreed to at the time of ordering apply to all orders ABB accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The...