151
T-Modell - 17/18 - Ausgabe 09/17 - 2891569 - BUE-0029-19EN
Appliances
9
Keep the water taps open until the water flowing out of the water taps has
no bubbles in it. This is the only way to ensure that the boiler is full of water.
Close all water taps.
Emptying the boiler:
Switch off hot water production.
Open the safety/drainage valve. To do this turn the knob (Fig. 193,1) par-
allel to the safety/drainage valve. The push button (Fig. 193,2) jumps out.
The boiler is drained to the outside by the safety/drainage valve.
Check whether the water has been drained completely from the boiler
(approx. 10 litres).
Operating modes
The hot-water heater with the boiler can be operated with various energy
sources.
Selecting operating mode:
Turn rotary push button (Fig. 191,6) until the menu symbol operating mode
(Fig. 192,3) flashes.
Press rotary push button.
Turn rotary push button until the desired operating mode is displayed:
z
Gas operation
z
Electrical operation (900 W)
z
Electrical operation (1800 W)
z
Gas and electrical operation (900 W)
z
Gas and electrical operation (1800 W)
Press the rotary push button to save the set operating mode. To revert to
the original setting: Press back button (Fig. 191,7).
The combination of gas operation and 230 V electrical operation shortens the
time required to heat up the vehicle.
Setting the fan:
Turn rotary push button (Fig. 191,6) until the fan menu symbol (Fig. 192,4)
flashes.
Press rotary push button.
Turn rotary push button until the required value is displayed:
z
OFF: Fan is switched off.
z
VENT: Air circulation
z
ECO: Low fan setting
z
HIGH: High fan setting
z
BOOST: Fast room heating. Boost is available if the current room tem-
perature is at least 10 °C below the selected room temperature.
Press rotary push button to save the value set. If you do not wish to change
the value originally set: Press back button (Fig. 191,7).
Z
230 V electrical operation is only possible when the vehicle is connected to
the 230 V power supply.
Z
Select the output level for 230 V electrical operation so that it corresponds
to the fuse protection of the 230 V connection (900 W for 3.9 A fuse,
1800 W for 7.8 A fuse).
Содержание Ixeo Time IT 590
Страница 2: ...T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Instruction manual ...
Страница 10: ...10 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Introduction 1 ...
Страница 56: ...56 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Pitching the motorhome 5 ...
Страница 118: ...118 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Gas system 7 ...
Страница 184: ...184 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Appliances 9 ...
Страница 248: ...248 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Special equipment 15 ...
Страница 262: ...262 T Modell 17 18 Ausgabe 09 17 2891569 BUE 0029 19EN Helpful notes 17 ...