14
Flash sequence
In the event of an error, the LEDs flash as follows:
z
On/off 0.5 seconds
z
Pause 5 seconds
Fault
Cause
Remedy
None of the LEDs comes
on, device is switched
on, operating voltage is
connected
Automatic restart is
blocked, e.g. following an
interruption of the power
supply
Reset the device (switch
off, wait 5 seconds,
switch on again)
After switching on (win-
ter and summer opera-
tion) none of the LEDs
comes on
No operating voltage
Check 12 V battery volt-
age, load battery if nec-
essary
Check all electrical plug
connectors
Appliance fuse or vehi-
cle fuse defective
Check appliance fuse or
vehicle fuse and replace
if necessary
After switching on, the
green LED comes on but
the heater does not work
The temperature set on
the control unit is below
room temperature
Set a higher temperature
on the control unit
Green LED comes on,
yellow LED flashes 1 x
(heater still in operation)
Risk of undervoltage;
battery voltage too low
< 10.4 V
Charge the battery
Green LED comes on,
yellow LED flashes 2 x
(no further operation)
Undervoltage; battery
voltage too low < 10.0 V
Charge battery or replace
Overvoltage > 16.4 V
Check battery voltage
and voltage sources (e.g.
charging unit)
Green LED comes on,
yellow LED flashes 4 x
After extended operation,
heater registers a fault
Summer operation with
empty water container
Switch off the device and
allow it to cool, fill boiler
with water
Warm air louvres blocked
Check outlet openings
Air circulation suction
system blocked
Remove blocking of air
circulation suction sys-
tem
Green LED comes on,
yellow LED flashes 5 x
Room temperature sen-
sor or cable defective
Contact customer service
Green LED comes on,
yellow LED flashes 7 x
Control unit or cable de-
fective
Contact customer service
Green LED comes on,
yellow LED flashes 8 x
Short circuit in heating el-
ement for frost control
Remove plug of heating
element on the electron-
ic control unit, replace
the heating element
Green LED comes on,
yellow LED flashes 9 x
approximately
30 seconds after the
heater is switched on
Regulator tap or gas iso-
lator tap is closed
Open regulator tap or
gas isolator tap
Gas bottle is empty
Change gas bottle
Содержание CityCar 2016
Страница 2: ...City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Instruction manual...
Страница 6: ...Contents 6 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN...
Страница 8: ...8 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Checklist before first journey of the vehicle...
Страница 12: ...12 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Introduction 1...
Страница 30: ...30 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Before the journey 3...
Страница 42: ...42 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Pitching the motorhome 5...
Страница 66: ...66 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Gas system 7...
Страница 98: ...98 City Car 15 16 Ausgabe 12 15 2616861 BUE 0090 00EN Appliances 9...