The live values of the sensor channels are updated at a rate of 100 Hz. The values are only updated
when the DIGIFORCE
®
9307 is ready to record measurements or is actively taking a measurement.
How to define the selectable list:
The parameterization of the selectable lists is done in the main
setup menue "Setup user defined values" (Note that this setting is specific for each measurement
program. For details refer to the DIGIFORCE
®
9307 operation manual, section 5.13 User defined
values.)
6.2 PLC inputs - Transfer from master to slave
Four bytes of PLC-In data for the DIGIFORCE
9307 are always transferred from the PROFIBUS
master to the DIGIFORCE
9307. These bits have the same function as the parallel PLC inputs to the
DIGIFORCE
®
9307 unit. (See detailed documentation of these signals within the DIGIFORCE
®
9307
operation manual, section 5.3.9 Assigning PLC outputs).
6.2.1 PLC inputs Byte 1 (master to slave)
PLC inputs Byte 1 (Master
Slave)
Valid values:
IN_PROG0
Bit 0 LSB
IN_PROG1
Bit 1
Set reserved bits to '0'
IN_PROG2
Bit 2
IN_PROG3
Bit 3
IN_PROG4
Bit 4
reserved
Bit 5
reserved
Bit 6
reserved
Bit 7 MSB
6.2.2 PLC inputs Byte 2 (master to slave)
PLC inputs Byte 2 (Master
Slave)
Valid values:
IN_STROBE
Bit 0 LSB
IN_ACK_OK
Bit 1
Set reserved bits to '0'
IN_ACK_NOK
Bit 2
IN_TEST_OP
Bit 3
IN_TEST_OPC
Bit 4
IN_AUTO
Bit 5
reserved
Bit 6
IN_REF_MEAS
Bit 7 MSB