PART 4-TRACER CALIBRATION
4.2.4 CAMERA ROTATION ADJUSTMENT
INTRODUCTION
The Camera Rotation Adjustment performed at the factory will usually be
sufficient for a field installation. In the event that the camera is removed from
the unit or the head assembly mounting plate is not parallel to the “Y” axis,
then this adjustment must be performed.
DETAILS
CHECK CURRENT SETTING
To check the Camera Rotation Adjustment, tape a white sheet of paper to the
tracing table as shown in the figure below. Then take a black Sharpie-type of
marker and hold or tape it against the tracing head with the tip touching the
paper. Move the machine in the Y axis to strike a horizontal line
approximately 1mm wide and a minimum of 100 mm long. The line must be
parallel to the Y axis.
Remove the pen. Jog the head away from the line and stop. Setup for a Trace
Left and lead into the center of the line. Press the Stop button when the head
is over a continuous section of the line. Push the “RED STOP” and “RIGHT
ARROW” buttons together. If the center LED is illuminated then this
adjustment is not needed. If either the right or left LED is illuminated,
perform the adjustment described below.
Figure 4.1 – Reference Trace Generation
Содержание 1100 CD
Страница 20: ...Figure 1 3 Slowdown Marker ...
Страница 34: ...BLANK ...
Страница 56: ...BLANK ...
Страница 58: ...Tools 40 Torch Lifter Controls 26 Tracer Function Keys 21 28 ...
Страница 63: ...PART 7 DRAWINGS PART 7 DRAWINGS ...
Страница 64: ...BLANK ...