Tay Thermostatic Bath Shower Mixer Deck Mounted
-
T2DB
Conditions for the use of thermostatic mixing valve
The thermostatic valve has been designed to be compliant with the relevant UK standards applicable to this type of product governed
by TMV2 standards and WRC. The valve is tested against BS EN 1111.
The valve will operate under low pressure but it is recommended that the cold water supply is at least 2 meters from the outlet of the
shower valve.
• This thermostatic valve is suitable for use with all water systems up to a maximum operating pressure of 5.0 bar, (beyond whi
ch we
recommend pressure reducing valves to be fitted.)
• The valve is provided with two outlets, which
are controlled by a flow control cartridge. Commonly used for a main bath spout or a
flexible
shower kit.
• An independent, flexible hot and cold water supply pipe is recommended for use to easy maintenance.
• If installing a shower pump always install the pump before the shower valve.
The list below shows the recommended limits for correct operation;
Low Pressure
Maximum Static Pressure – Bar
10
Flow Pressure, Hot & Cold - Bar
0.2 to 5
Hot Supply Temperature - °C
55 to 65
Cold Supply Temperature - °C
Equal to or less than 25°
The British Burns Association recommends 37 to 37.5°C as a comfortable bathing temperature for children. In premises covered b
y the
Care Standards Act 2000, the maximum mixed water outlet temperature of 43°C.
Important
• We recommend that this product is installed by a qualified professional contractor. Such as a plumber who is certified by NVQ
(National Vocational Qualification) or SNVQ (Scottish National Vocational Qualification) Level 3
• Please check this product immediately to ensure that it has not been damaged and is complete. Before installation, please mak
e
sure this product is the correct model and you have all the parts required for installation and using.
• This valve is a mixing device and therefore requires the water supplies to be reasonably balanced, otherwise we recommend
a pressure reducing valve to be fitted.
• Please flush the water system to ensure that no metal swarf, solder, and other impurities can enter the valves.
• Turn off water supply before commencing work, this should be done at the isolating valves of inlet feeds if fitted or main stop
cock.
• Please read these instructions carefully and keep it for future reference.
INSTALLATION INSTRUCTIONS
Options:
Burlington has 2 different style handles for your selection,
when using these additional handles the indices will need
to be utilised from the original handles.
Anglesey
Birkenhead
NOT INCLUDED IN THE BOX