background image

3.20

 

If  any  material  such  as  plastic  melts  onto  the  surface  of  the  glass,  turn  the  appliance 

off

  and 

allow it to cool. Do not remove the material when hot.

 A proprietary ceramic hob cleaner such 

as ‘hob brite’ can be used to clean the glass.  Only clean the appliance when cold. 

3.20.1

 

On  no  account  must  the  air  inlets  under  the  stove  or  outlet  grills  (see  diagram  below)  be   
obstructed. 

 

 

 

4.

 

WARNINGS 

4.1

 

Read the instructions before using this appliance. 

4.2

 

This appliance requires installation by a competent qualified person. 

4.3

 

Use only in a correctly sized and ventilated area. 

4.4

 

Once the ceramics have been positioned in accordance with the installation instructions, they 
must not be moved except for servicing. 

4.5

 

The surfaces of the appliance become very hot during use. 

4.6

 

Before cleaning or maintenance switch fire OFF and allow to cool. 

4.7

 

Any  purpose  provided  ventilation  should  be  checked  regularly  to  ensure  it  is  free  from 
obstruction. 

 

 

 
 

5.

 

Hearths, floor protection and carpets 

5.1

 

This appliance does not need a hearth and can be used on wooden, laminate floors and non-
combustible  surfaces.  It  must  not  be  placed  directly  onto  carpets  or  rugs.  Where  the  floor  is 
carpeted,  the  carpet  must  finish  100mm  clear  of  the  appliance  legs  and  be  fully  removed 
underneath.  Loose  rugs  should  be  kept  well  away  from  the  appliance  (warn  the  customer  of 
this). 

5.2

 

Standing the appliance directly on a floor can lead to discolouration and / or drying out. 

5.3

 

When  a  hearth  is  used,  the  top  surface  can  be  wood  but  be  aware  that  heat  can  discolour 
certain finishes over a period of time and can dry out poorly seasoned wood causing splitting. 
The  hearth  should  be  100mm  larger  than  the  appliance  all  round  and  minimum  12mm  thick. 
Carpets can come to the edge of the hearth. 

 

Содержание G4121

Страница 1: ...HESE INSTRUCTIONS WITH THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4121InstUser...

Страница 2: ...GHTING EASIER BURLEY APPLIANCES IS THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVERY SINGLE GAS FIRE IT PRODUCES BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTO...

Страница 3: ...ld cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the pilot...

Страница 4: ...unit to its original position REPLACE THE HEATSHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat shiel...

Страница 5: ...owly anticlockwise to the ignition position A click will be heard and the pilot under right side of fuel bed should light If it does not repeat the operation a few times to purge any air in the pipe C...

Страница 6: ...gory I2H I3P Supply Pressure 20mBar 37mBar Inlet Pressure 20mBar 37mBar Heat Input Net High 3 5kW 3 5kW 250g h Low 1 7kW 1 7kW 120g h Inlet Connection 8mm Compression 8mm Compression Injector stereo 3...

Страница 7: ...combustible surface 3 8 No furniture soft furnishings decorations wall coverings or curtains must be within 1 metre of the appliance and its convection outlets 3 9 The appliance must not be installed...

Страница 8: ...fore cleaning or maintenance switch fire OFF and allow to cool 4 7 Any purpose provided ventilation should be checked regularly to ensure it is free from obstruction 5 Hearths floor protection and car...

Страница 9: ...igid tubing such as copper pipe Before working on pipework plug open ends A servicing isolator is supplied with the appliance and this should be used to permit disconnection for servicing etc All gas...

Страница 10: ...fitted similar to the Natural Gas fire The base log locates onto the burner and the front log is pushed to the extreme left hand side as shown Take care to locate them correctly to ensure clean combus...

Страница 11: ...k Failure The gap between the pilot electrode and the pilot should be 3 5 4 5mm and normally adjustment is not necessary Check the fire lights at least 3 times out of 5 attempts Visually check that th...

Страница 12: ...outlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading Light the fire u...

Страница 13: ...0 The appliance must not be used in rooms where the atmosphere is likely to contain water or chemical vapours which may adversely affect the appliance or its finish 11 Do not use whilst painting decor...

Страница 14: ...test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least 15 mi...

Страница 15: ...ult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filter...

Страница 16: ...st over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can creep in It is worth mea...

Страница 17: ...y gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than Gas Safe registered installer formerly CORGI or our own en...

Страница 18: ...ling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up but are...

Страница 19: ...19...

Страница 20: ...fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk Email...

Отзывы: