6
1.11
SLIDE CONTROL
1.
Slide the control lever firmly to the right of its travel and listen for the spark generator
clicking which should light the pilot.
2.
Continue to hold for a further 10 seconds.
3.
If the pilot fails to stay alight, slide the control lever to the left of its travel (off) & wait for 3
minutes & repeat the process.
4.
Once the pilot is alight, slide the control lever to the desired position.
5.
To turn the fire off slide the control lever to the left of its travel.
6.
The off position on the bezel may not correspond exactly with the control lever. This is only
intended as an indication.
1.12
Battery Replacement
Behind the ash pan cover, located towards the right of the burner is the spark generator
which is fitted with the battery facing you. Flick out the battery from the right hand end of the
battery holder and remove battery. Replace with a good quality 1.5v AA battery ensuring the
polarity markings on the battery correspond with the markings on the battery holder. Check
the spark generator clicks when the control linkage is operated.
1.
TECHNICAL DATA
Refer to the appliance data badge (affixed behind control door)
ENSURE THAT THE LOCAL CONDITIONS OF USE CORRESPOND TO THE INFORMATION ON THE DATA
BADGE.
-
THIS PRODUCT CAN NOT BE CONVERTED -
Natural Gas G20
LPG (Propane) G31
Category
I2H
I3P
Supply Pressure
20mBar
37mBar
Inlet Pressure
20mBar*
37mBar*
Heat Input (Net)
(High)
3.5kW
3.5kW (250g/h)
(Low)
1.7kW
1.7kW (120g/h)
Inlet Connection
8mm Compression
8mm Compression
Injector
stereo 300
stereo 120
*
The inlet pressure must be
within +/- 1mBar
of specification with
all
gas appliances in the house
switched on
and also
with just the appliance operating. If outside of this tolerance the fault is most
likely to be in the installation pipe work or service governor at the meter. If the problem is the meter
governor, this is the property of the gas service provider (such as Transco / National Grid 0800 111999
or Bord Gais) and they should be called to rectify this. The fire will not operate correctly if the
pressures are incorrect.
2.
UNPACKING THE APPLIANCE
2.1
Carefully examine the carton for damage before unpacking. If it is obviously damaged, consult
the supplier as to whether to proceed with the installation.
2.2
Make sure the carton is stood upright and open the top. Remove the cardboard top fitting and
place to one side; this box can be used as a hearth protector when installing the fire.
2.3
Remove the fittings boxes contained within and open them and check the condition of the
contents. Remove the fire and examine its general condition.
2.4
If satisfied by the general condition proceed with the installation. If in any doubt, seek advice
from the supplier in the first instance.
Please read these instructions fully before proceeding
even if you have fitted this model before.
Содержание G4121
Страница 19: ...19...