12
15.
Servicing Instructions
Before commencing any servicing, ensure that the gas is isolated and the appliance is cool.
Cleaning – The casing should be wiped with a cloth dampened in soapy water. The glass may be
cleaned with any non-abrasive cleaner such as ‘hob brite‘.
The coals contain refractory fibre (RCF). Excessive exposure to these materials may cause temporary
irritation to the eyes, skin and respiratory tract; consequently, it makes sense to take care when
handling these parts to ensure that the release of dust is kept to a minimum. We recommend the use
of a HEPA filtered vacuum to remove any dust and soot accumulated in the appliance before and after
working on it. When replacing these articles, they should not be broken up, but sealed in heavy duty
polythene bags labelled RCF Waste’, which may be disposed of at a tipping site licensed for industrial
waste. Protective clothing is not required, but normal hygiene rules of no smoking, eating or drinking
in the work area should be followed.
Controls – The system for monitoring the oxygen supply to the burner is not adjustable and must not
be put out of operation. Should the oxypilot system need to be replaced, the original manufacturer’s
parts must be used.
Injectors
–
Only
original
manufacturer’s injectors must be used.
The unit
must
be serviced at least once per year, preferably at the beginning of the heating season. All
servicing must be carried out by a qualified service person. A combustion analysis check should be
carried out using an analyser to BS7967 and sampling the entire width of the combustion product
outlet. Ratio of CO/CO2 should be less than 0.002 within 30 minutes. (20ppm CO per 1% CO2) A
reading of CO in the room centre should give a rise of less than 9ppm over ambient, peak reading.
Light the fire using the method in the instructions and ensure that the pilot lights consistently and the
pilot flame envelopes the thermocouple evenly, it is located at the front on the right-hand side.
The pilot should hold in 6-10 seconds. Turn control to main burner, this should light smoothly. Ensure
the valve gives adequate turn down and the thermostat bulb reduces the burner rate to low when
heated.
Locate thermostat bulb in a cool place off the appliance and preferably outside of any inglenooks, to
ensure it is sensing room air temperature.
Run the appliance for 10 minutes, ensuring burner flames settle evenly.
The gas manifold pressures are factory pre-set using highly accurate equipment, and
must
not be
altered.
The catalyst is unlikely to need replacement during the life of the appliance. The appliance should be
inspected before use and at least annually by an authorised service person. More frequent cleaning
may be required due to accumulation of lint and dust from carpeting etc. Hoover under fire regularly
paying attention to the area around pilot.
It is imperative that the control compartments, burners and circulating air passageways of the
appliance be kept clean. Replacement parts are available from your local dealer.
BURLEY APPLIANCES ARE THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVERY
SINGLE GAS FIRE IT PRODUCES. BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY
APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER.
Due to our policy of continual improvement and development the exact accuracy of descriptions and
illustrations cannot be guaranteed.