Burley G4121 Скачать руководство пользователя страница 10

10 

 

9.

 

Laying the Logs 

Open the hinged door on the appliance. This is secured by a 10mm nut to gain access to the logs. On 
no account should the appliance be operated whilst  the door is open except for brief periods during 
maintenance. Do not lay the log matrix in any way other than that shown.  Check the log layout as they 
may have been damaged during transit. 

LOG LAYOUT (NATURAL GAS)

 

The  rear  matrix  and  front  log  should  only  need 
removing  for  servicing.  The  rear  matrix  locates  onto 
the burner and the front log is pushed to the extreme 
left  hand  side.  Take  care  to  locate  them  correctly  to 
ensure clean combustion. No additional logs should be 
added to the fire.  
Note  the  pilot  position  on  the  right  hand  side  of  the 
burner.

 

 

 

 

 

LOG LAYOUT (LPG) 

The rear matrix and front log are fitted similar 
to  the  Natural  Gas  fire.  The  base  log  locates 
onto the burner and the front log is pushed to 
the extreme left hand side as shown. Take care 
to  locate  them  correctly  to  ensure  clean 
combustion.  No  additional  logs  should  be 
added to the fire.  
Note  the  pilot  position  on  the  right  hand  side 
of the burner.

 

 
*Note – The 2 top logs will be supplied glued 
in position and should not be removed or repositioned. If they become detached then they can be 
fitted as per the diagram but must on no account be discarded or fitted in any other way. 

 

Front Log - IMPORTANT - the log must be this way up! Placed fully to the left NG & PR 

 

Pilot side

 

 

 

Always secure the door closed after laying the fuel effects. 

 

Do not attempt to use any unit with broken or damaged glass. 

 

Do not use the fire with broken logs. 

 

Do not add any additional fuel elements to the fire. 

 

Do not use similar looking parts from other appliances, use only genuine spare parts. 

 

Do not use the appliance for burning waste.

 

Содержание G4121

Страница 1: ...HESE INSTRUCTIONS WITH THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4121InstUser...

Страница 2: ...GHTING EASIER BURLEY APPLIANCES IS THE ONLY COMPANY TO BENCH RUN AND THOROUGHLY TEST EVERY SINGLE GAS FIRE IT PRODUCES BURLEY IS IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTO...

Страница 3: ...ld cease and be replaced with the ticking sound of the spark igniter When the pilot flame is lit the igniter will stop another acoustic signal will confirm the pilot has been established if the pilot...

Страница 4: ...unit to its original position REPLACE THE HEATSHIELD over the unit Press here and slide down CAUTION With the exception of battery replacement the battery holder must be located within the heat shiel...

Страница 5: ...owly anticlockwise to the ignition position A click will be heard and the pilot under right side of fuel bed should light If it does not repeat the operation a few times to purge any air in the pipe C...

Страница 6: ...gory I2H I3P Supply Pressure 20mBar 37mBar Inlet Pressure 20mBar 37mBar Heat Input Net High 3 5kW 3 5kW 250g h Low 1 7kW 1 7kW 120g h Inlet Connection 8mm Compression 8mm Compression Injector stereo 3...

Страница 7: ...combustible surface 3 8 No furniture soft furnishings decorations wall coverings or curtains must be within 1 metre of the appliance and its convection outlets 3 9 The appliance must not be installed...

Страница 8: ...fore cleaning or maintenance switch fire OFF and allow to cool 4 7 Any purpose provided ventilation should be checked regularly to ensure it is free from obstruction 5 Hearths floor protection and car...

Страница 9: ...igid tubing such as copper pipe Before working on pipework plug open ends A servicing isolator is supplied with the appliance and this should be used to permit disconnection for servicing etc All gas...

Страница 10: ...fitted similar to the Natural Gas fire The base log locates onto the burner and the front log is pushed to the extreme left hand side as shown Take care to locate them correctly to ensure clean combus...

Страница 11: ...k Failure The gap between the pilot electrode and the pilot should be 3 5 4 5mm and normally adjustment is not necessary Check the fire lights at least 3 times out of 5 attempts Visually check that th...

Страница 12: ...outlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading Light the fire u...

Страница 13: ...0 The appliance must not be used in rooms where the atmosphere is likely to contain water or chemical vapours which may adversely affect the appliance or its finish 11 Do not use whilst painting decor...

Страница 14: ...test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least 15 mi...

Страница 15: ...ult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air filter...

Страница 16: ...st over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can creep in It is worth mea...

Страница 17: ...y gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than Gas Safe registered installer formerly CORGI or our own en...

Страница 18: ...ling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up but are...

Страница 19: ...19...

Страница 20: ...fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk Email...

Отзывы: