SAW sensor - Parameter
Type 8098
13.7
Setting the parameters of the totalizers
13.7.1
Giving a user defined name to each totalizer
The name is used to identify the process value in the user defined views and in all the menus where the
process value is displayed.
By default, the names associated to the totalizers are
Totalizer 1
and
Totalizer 2
.
To add a user defined name to the default name of a totalizer, do the following:
→
Select the device in the navigation area.
→
SAW sensor
→
Parameter
→
Stand. meas. values
→
Totalizer 1
or
Totalizer 2
→
Value name
→
Enter the name. The name can have up to 19 characters.
→
Apply
The name is changed.
13.7.2
Selecting the counting direction of each totalizer
By default, the counting direction of both totalizers is
Positive only
.
The possible counting directions are:
•
Positive only
: the totalizer counts the volume of liquid that flows in the direction defined as positive, i.e. in
the same direction as the arrow located on the front of the device.
•
Negative only
: the totalizer counts the volume of liquid that flows in the direction defined as negative, i.e.
in the direction opposite to the direction of the arrow located on the front of the device.
•
Both
: the totalizer counts the volume of liquid that flows in the direction defined as positive but deducts
the volume of liquid that flows in the direction defined as negative.
To change the counting direction of each totalizer, do the following:
→
Select the device in the navigation area.
→
SAW sensor
→
Parameter
→
Stand. meas. values
→
Totalizer 1
or
Totalizer 2
→
Counting direction
→
Select a counting direction.
The counting direction is changed.