Type 8756
Maintenance
english
62
DANGER!
Burn hazard and fire hazard that are due to hot surface of the
product.
▶
Do not touch the hot surface with bare hands.
▶
Wear safety gloves to touch the product.
▶
Keep the product away from any highly flammable materials
or fluids.
WARNING!
Risk of injury that is due to escape of the fluid.
Contact with the operating fluid, its reaction products and va-
pours can cause injuries.
Inhaled vapours can be harmful.
▶
Observe all applicable accident protection and all applicable
safety regulations relating to the operating fluid used.
WARNING!
If you open the housing, risk of injury from malfunction and
risk of product failure.
Sensitive product parts are used to measure the flow rate and to
regulate the flow rate.
▶
Do not open the product housing.
▶
Only carry out the cleaning work and maintenance work on
the product that are described in the Operating Instructions.
▶
Only the manufacturer can carry out further work and calibra-
tion.
WARNING!
Risk of injury that is due to improper maintenance.
▶
Only trained personnel can do the maintenance work. Person-
nel must use suitable tools.
▶
Secure the installation against unintentional actuation.
▶
Ensure a controlled restart after maintenance.
9.2
Replace the memory card
To replace the memory card on the product, do the following:
De-energise the product.
With a TX8 screwdriver loosen the screws of the cover. Re-
move the cover.
Remove the old memory card from its slot.
Pay attention to the insertion direction of the memory card.
The following figure shows the final position of the memory
card in the product.
With a TX8 screwdriver, screw the cover to a torque of
1.2 N·m, that is 0.9 lbf·ft.
Restart the product to write the product data on the new
memory card. Possible problems related to the memory card
are given in chapter: