Burkert 2000 INOX Скачать руководство пользователя страница 6

6

Assembly

Type 2000 INOX

ASSEMBLY

DANGER!

Risk of injury from high pressure in the system!

 

Turn off the pressure and vent the lines before loosening 

lines or valves.

WARNING!

Risk of injury from improper assembly!

 

Installation must only be carried out by authorized techni

-

cians and with the appropriate tools!

Risk of injury from unintentional activation of the system and 

uncontrolled restart!

 

Secure system from unintentional activation.

 

Following assembly, ensure a controlled restart.

Risk of crushing from moving pneumatic connection!

 

When opening and closing the device, do not touch the 

moving pneumatic connection.

 

Do not reach into the area immediately above and below the 

control air connection.

6.1 

Preparatory work

 

Before connecting the valve, ensure the pipelines are flush 

(stress-free).

 

Clean pipelines (sealing material, swarf, etc.).

Devices with welded body:

Remove the actuator from the valve body:

 

Clamp the valve body into a holding fixture.

NOTE! 

Damage to the seat seal or the seat contour!

 

Open the valve for control functions A: Pressurize the lower 

pilot air port with compressed air (5 bar).

 

Place  a  suitable  open-end  wrench  on  the  wrench  flat  of  the 

nipple.

 

Unscrew the actuator off the valve body.

Devices with threaded body:

 

Only disassemble the actuator if required by the customer.

6.2  Installation

6.2.1  Installing valve housing in pipeline

For welded housings:

 

Weld valve housing in pipeline system.

 

Check graphite seal and, if required, replace.

Graphite seal

For other housing models:

 

 Connect valve housing to pipeline.

english

Содержание 2000 INOX

Страница 1: ...Quickstart English Deutsch Fran ais Type 2000 INOX 2 2 way angle seat valve 2 2 Wege Schr gsitzventil Vanne si ge inclin 2 2 voies...

Страница 2: ...issioning of the equipment by way of example A detailed description of the equipment can be found in the operating instructions for Type 2000 INOX on the Internet at www burkert com 2 CONTACT ADDRESS...

Страница 3: ...n the separate Ex type label For use observe the additional information enclosed with the device together with safety instructions for the explosion risk area Devices without a separate Ex type label...

Страница 4: ...when in perfect condition and in consideration of the operating instructions The general rules of technology apply to application planning and operation of the device 5 TECHNICAL DATA 5 1 Conformity...

Страница 5: ...or control pressure is exceeded lines or device may leak and burst For control function B a too low control pressure may result in leaks Do not exceed medium pressure and control pressure For control...

Страница 6: ...below the control air connection 6 1 Preparatory work Before connecting the valve ensure the pipelines are flush stress free Clean pipelines sealing material swarf etc Devices with welded body Remove...

Страница 7: ...ed when screwed in Screw actuator into the valve housing Observe tightening torque 40 3 Nm 6 3 Pneumatic connection WARNING Risk of injury from unsuitable connection hoses Hoses which cannot withstand...

Страница 8: ...relevant wear part Description see Operating Instructions on the Internet 8 1 Cleaning Commercially available cleaning agents can be used to clean the surface of the device NOTE Before cleaning check...

Страница 9: ...www burkert com...

Отзывы: