background image

FACTORY SET VOLTAGE 115 V

CONNECTION VOLTAGE 

CHANGING:

Before changing the  

voltage connection:

A) Ensure the power to  

the pump is disconnected.  

B) Open motor junction box cover.

C) Please select the up knob  

position for 115V or down  

knob position for 230V.

D) Connect to appropriate voltage.

E) Close motor junction box.

WWW.BURCAM.COM

 2190 Boul. Dagenais West 

TEL: 514.337.4415

 LAVAL (QUEBEC)  

 

FAX: 514.337.4029

 CANADA

 H7L 5X9                                     [email protected]

Your pump has been carefully packaged at the 

factory to prevent damage during shipping. 

However, occasional damage may occur due 

to rough handling. 

Carefully inspect your 

pump

 for damages that could cause failures. 

Report any damage to your carrier or your 

point of purchase.

INSTALLATION

INSTRUCTIONS

MODELS

503121S/503221S

AND  

BY- PRODUCTS LIKE

503127S,  503128S,

503228S,  503131S,

503231S, ETC.

JET PUMP

Please read these 

instructions

 carefully. 

Failure 

to comply to  

instructions and 

designed

 operation of 

this system,

 may

 void 

the warranty.

© 2014 BUR-CAM  Printed in Canada 510059

Suction connection

 Discharge  connection

PRIMING PROCESS

Follow all these inside step by step instructions to install your pump. Use teflon tape on 

all threads. (1) Fill the suction line with water and connect it to the suction inlet.  

(2) Remove the priming plug and fill the pump body with water. (3) Screw the plug to 

the priming inlet. (4) Turn the power on. The pump should deliver water to the plumbing 

line within 30 seconds. If not, unplug the pump and repeat the process at step 2.

4

1

2-3

Содержание 503121S

Страница 1: ...Report any damage to your carrier or your point of purchase INSTALLATION INSTRUCTIONS MODELS 503121S 503221S AND BY PRODUCTS LIKE 503127S 503128S 503228S 503131S 503231S ETC JET PUMP Please read thes...

Страница 2: ...1 well seal elbow 750860 1 1 male adaptor 750865 or 750871 and 1 1 to 1 male adaptor 150181 8 1 stainless steel clamps 750885 Teflon tape Tank installation Desired length of 1 braided hose 750919 to...

Страница 3: ...temperatures and good ventilation should be considered as well to provide the pump an environment for long life Locating the pump as close as possible to the water source will reduce friction losses e...

Страница 4: ...o the basement wall Locate the suction inlet in the front of the injector Thread an adaptor into inlet using teflon tape Do not over tighten Cut the desired length of pipe from pump location to the we...

Страница 5: ...or removing air at the snifter valve 2 PSI below pressure switch ON setting Turn power back on to pump Your tank is now well precharged Run the pump through a few cycles to verify that it works prope...

Страница 6: ...tage See above drawing on right Pressure switch setting start stop 20 40 or 30 50 has been made at the factory Adjustments may be done to give other operating pressures Adjustment or modification of s...

Страница 7: ...well seal and piping into well casing STEP 2 Cut poly pipe and install the check valve Check valve close to pump STEP 3 Insert well seal elbow through the seal and attact to pipe STEP 7 You may insta...

Страница 8: ...djust air pressure To home s plumbing distribution line Pressure switch 1 4 connection if not included with the pump Pressure gauge 1 4 connection Drain valve 1 2 connection 1 MNPT or 3 4 FNPT connect...

Страница 9: ...Ref Part Description 10 510065 Diffuser Plate 11 510051 Diffuser Plate O Ring 12 510050 Diffuser Plate Washers 3 13 510049 Diffuser Plate Screws 3 14 510069 Venturi 15 510046 Nozzle 16 510056 1 4 NPT...

Страница 10: ...on line Gaz in water Airlogged tank galvanized Turn switch to on position Replace Reset Clean Replace Replace Prime with clean water Check pipe and pipe connections Clean Clean Check foot valve level...

Отзывы: