WEEKLY
Mixing Chamber Parts Cleaning
• Remove the powder mixing chambers, steam traps, frothers and mixing chamber bases.
• Remove the dispense hoses from the dispense nozzle assembly.
• Clean all parts removed in warm soapy water. Use the provided cleaning brush (PN 26367.0000) to
clean bores and orifices. Rinse in cold water.
• Prepare one-gallon (3.8 liter) of sanitizing solution with at least 100 ppm of available chlorine in 120°F
(48.9°C) water. Soak all cleaned parts in sanitizing solution for 5 minutes, then allow to air dry.
• Rinse cleaning brush, dip in sanitizing solution, and brush the bore of dispense nozzles
NOTE: Repeat this procedure for each nozzle separately.
• When reassembling parts, be sure to align arrow on frother disk with flat on whipper motor shaft, and
rotate tab on whipper base clock wise to the vertical position to lock mixing chamber.
a
b
c
1
2
3
5
6
4
SERVICE ACCESS
8. Close the front door to resume normal operation.