ITB Training Manual
8
Level 2 Programming
Press and hold the hidden switch for 5 seconds
This function allows the operator to select the language used for the display.
This function allows the operator to select if numeric settings are displayed in English or
Metric units.
This function allows the operator to view the brew settings for the various tea recipes
stored into the brewer. It also allows the operator to modify any of the brew settings for a
particular recipe stored in the brewer.
This function allows the operator to assign a recipe to (or disable) each of the 3 brew
switches (A, B, C). Any saved recipes listed under “Review Recipes” can be assigned to
a brew switch. Only one recipe per brew switch is allowed.
This function allows the operator to adjust the brew water temperature in the tank. This
also sets the hot water faucet dispense temperature.
This function allows the operator to set the minimum temperature allowable to start a
brew cycle. The range can be from 2° to 20° F below the set temperature. The water
must be at the Ready temperature or higher for the display to indicate Ready To Brew. If
brew lockout is enabled, the brewing process won’t start below this Ready temperature.
This function allows the operator to choose whether or not to display an advertising
message. An ad can be saved to the brewer by writing the ad using the programming
commands. This message will be displayed when the brewer is not in use.
This function allows the operator to enable the sanitation function and set the time be-
fore a cleaning alert will be displayed.
This function allows the operator to enable the Energy Savings mode function and set
the idle time. Once the set idle time has expired, the operator can choose to have the
heaters either turn off, or reduce the tank holding temp to 140° F (60° C).
This function allows the operator to enable the Freshness Alert and set the expiration
time. The expiration time is the amount of time the product is allowed to sit in the server/
dispenser before a fresh batch is brewed.
This function allows the operator to adjust the sensitivity of the refill circuit. This is main
-
ly a troubleshooting feature. Water in different geographical locations can have different
conductivities. By adjusting the sensitivity of the refill circuit, this will allow the brewer to
operate under various water conditions.
This function allows the operator to view or enter the actual flow rate coming out of each
sprayhead. This is Not used to control the actual flow rate, but to tell the internal proces
-
sor how fast the water is flowing.
UNITS
Metric
ENG
DONE
REVIEW RECIPES ?
NO
YES
ASSIGN RECIPE ?
NO
YES
SET TEMP 200
O
(-)
(+)
DONE
ENABLE ADS ?
NO
YES
DONE
ENABLE SANITATION
NO
YES
DONE
ENABL ENERGYSAVR
NO
YES
DONE
ENABLE FRESH TIMER
NO
YES
DONE
XX REFILL XXX
(-)
(+)
DONE
SPRAY OZ/M: XX.X
(-)
(+)
DONE
Set Language?
NO
YES
READY DEGREE 5
O
(-)
(+)
DONE