manual-rmp210-rmp3545-en-18
Page
10 / 16
If the [START/STOP] button is pressed during the countdown period, the relay will
de-energize and time remaining is shown on the display.
The timer can also be started and stopped from the external connections.
When the set time reaches zero the unit emits an audible signal, the relay de-energizes and
the set time is indicated on the display.
Please note:
If the [START/STOP] button is pressed and the time is zero, a bell symbol is
shown on the display and the relay will energize. Pressing the button again will de-energize
the relay.
Resetting to the time
Pressing the [RESET] button will set the time back to the start time.
Time reset
Pressing all three buttons together will set time to zero.
Total Reset
Press and hold down all three buttons for approx four seconds.
Data Storage on Loss of Power
On loss of power the countdown will stop and the relay de-energize. The time remaining will
be stored.
When power is resumed the remaining time will be shown and the timer will need to be restarted.
Setting the heater
The upper and lower heating levels can be
programmed separately.
Both thermostats are set to a maximum oper-
ating temperature of 250 ° C.
The heating rate is programmed at the fact-
ory with 6°C/min, but is in principle adjustable
to other values. Please contact us for the ori-
ginal instructions for the thermostats.
The green display value corresponds to the
current heating-up specification (TARGET).
The upper, red value of the respectively reached heating temperature (CURRENT).
Adjustment of the default temperature:
Press the button (MODE) and then the arrow keys to set the desired heating temperature, for ex-
ample to 175°C as shown in this figure.
Then press the button (MODE) again to save the selected value. The heating up can start now.
The thermostat has a "soft" heating control, which should avoid “overshooting” the set temperature.
For this reason, the temperature is ramped up gradually to the set default value.
The LED (OUT) indicates whether the heater is on or off.
The temperature to be set depends on the specifications of the material manufacturer and on the
gelling temperatures of the prepregs, as well as on the age of the prepregs.
ATTENTION: If the set temperature is too low or the process time too short, this can lead to rejects
and delamination. Both destroy the multilayer circuit.
Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany
Tel.: +49 (0) 2292/9 28 28 - 0, Fax: +49 (0) 2292/9 28 28 - 29, E-mail: [email protected]