Power off Unit & Switch Terminals
Upgrade Firmware
1
2
WARNING:
If wires are to be buried or covered, use conduit to protect the wires.
(Continued on back)
The following procedures are general steps for a typical installation. For additional information, please contact Technical
Support at 1-800-229-3404 or [email protected].
1
Open
Unit
cover and power down the
Unit
.
2
Disconnect
Satellite Termina
l cable from
Unit
.
3
Unmount the
DMR-800 Satellite Terminal
.
4
Mount
IDP Satellite Terminal
in existing mounting bracket using the
included screws. Ensure terminal is pointing due south of Mexico.
5
Connect
IDP Satellite Terminal
to
Unit
.
6
Power on the
Unit
.
Replacing the Satellite Terminal
WARNING
:
To prevent electrostatic discharge (ESD) damage when handling electronic equipment, always wear an anti-static
wrist strap attached to an unpainted, grounded metal object. Ensure the wrist strap has maximum contact with bare skin.
1
Attach
FUT
to
Unit’s Firmware Upload
serial port. The update begins automatically.
2
LED lights on the
FUT
:
Status
LED light indicates when
FUT
is updating or complete.
Activity
LED light flashes during the verification and update process.
IMPORTANT:
Unit must complete packet transmission to complete the update.
If packet transmission is not successful, repeat the firmware update process.
Red FUT
(part no. 826183-100)
IMPORTANT:
Do not turn off the unit during the update
process.
3
When the
Completed
status light turns on and the
Activity
light turns off,
disconnect the
FUT
.
4
LED lights on the
Unit
:
The
Acquiring Signal
light flashes to indicate
Unit
is searching for satellite
signal.
The
Packet Queue
light flashes to indicate
Unit
is transmitting. The light turns
off when Bullhorn Web receives the packet.
Unit
automatically sends a packet when update is complete to register the
new terminal with the
Unit
.
IMPORTANT:
Wait until the
Unit
’s
Radio
LED is a solid green before proceeding.
Blue FUT
(part no. 826183-000)
RM4010
Installation and Configuration
Quick Reference Guide
Part No. 122240-000 Rev. 0
1 of 2
August 2019
Required Tools
IDP Satellite Terminal Upgrade
Quick Reference Guide
Field Update Tool (FUT) -
Blue
FUT for
RM4010
or
RM4011
Red
FUT for
RM4013
Anti-static wrist strap
Adjustable wrench
Small Phillips head screwdrive
r
Small slotted screwdriver
Windows
®
Laptop PC
USB Mini-b cable
Bullhorn
®
Tools configuration software
Optional Hardware/Software
RM4011 Port, Switch, and LED Lights
NOTE:
A replacement fuse is included in the
IDP Conversion Kit
in the event the unit’s fuse is blown. For additional informa-
tion, refer to the
RM4000 Series User Guide
available on the Bullhorn RMU Support Site (support.aiworldwide.com).