BULLDOG SideWinder

 

Heat Pump

 

 

 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 
 
 
 

 
 
 

 
 
 

 
 
 

 

 

Only qualified personnel should install, 

service, and repair the equipment. 

SideWinder 
Models: SWD008- SWD015 

 

 

 
 
 

www.bulldogheatpump.com 

 

 

Содержание SideWinder SWD008

Страница 1: ...ce Manual is Subject to Change without Notice Last Revised June 2018 Installation Operation Maintenance BULLDOG SideWinder Heat Pump Only qualified personnel should install service and repair the equi...

Страница 2: ...19 Before calling technical support please have the model and serial number of the unit ready For Parts For replacement parts please call your local Bulldog Representative with the model and serial nu...

Страница 3: ...ctrical components ONLY trained and qualified personnel should install repair or service the equipment WARNING The installation of the SideWinder Heat Pump and all associated components parts and acce...

Страница 4: ...he unit in an upright position may result in permanent damage to the unit Dropping the unit or exposing it to extreme shock or vibration may also result in permanent damage to the interior components...

Страница 5: ...teps required to successfully install a SideWinder unit 1 Remove packaging and inspect the unit Check for shipping damage or material shortage file a freight claim and notify your sales representative...

Страница 6: ...y with all applicable codes and regulations It is the responsibility of the installing contractor to ensure adequate service clearance for regular maintenance or for repair in place is exercised The i...

Страница 7: ...Installation Operation and Maintenance Manual INSTALLATION STEPS 1 Screw discharge plate onto hanging bracket prior to mounting Unscrew the front stop screws on the flanges of the hanging bracket whi...

Страница 8: ...ensure the edge of the hinged panel is flush with the finished wall when closed Figure 4 Vertical distance is to be a minimum of 3 4 from the top of the hanging bracket This alignment will ensure the...

Страница 9: ...odes and regulations DO NOT bend or kink supply lines or hoses If supplied Supply and return ultra flex hoses 3 4 available from the factory are fitted with swivel joint fittings at one end to allow r...

Страница 10: ...ance Manual is Subject to Change without Notice Last Revised June 2018 8 BULLDOG SideWinder Installation Operation and Maintenance Manual WIRING 1 Wire room thermostat to electrical panel as indicated...

Страница 11: ...and do not operate units during the construction process The BULLDOG Heat Pump provides year round cooling and heating as controlled by the unit thermostat or by a direct digital controller The BULLDO...

Страница 12: ...tat terminal Cool Call Y on thermostat terminal Fan Call G on thermostat terminal Auxiliary A on thermostat terminal Compressor shutdown 24V AC signal thru O O Providing a continuous 24V potential to...

Страница 13: ...Power ON timer Compressor operation is delayed for approximately 5 minutes after restoration of power This prevents all units from coming on line at the same time when power is restored It also preve...

Страница 14: ...e set to alarm however if the open switch closes within 10 minutes a restart cycle is initiated The restart cycle begins with a 10 minute delay after which if there is a cool call in place and all oth...

Страница 15: ...nsate level sensor is a 100 ohm thermistor that is heated for 15 seconds every 4 minutes Its temperature is measured at the beginning of the heat cycle and again at the end of the heating cycle If the...

Страница 16: ...esent day thermostats operate in this manner there are others that may or may not work properly The following should be checked out for satisfactory performance prior to installation 1 Heat Pump Therm...

Страница 17: ...board 24V power This capability allows unit or compressor shutdown based on a door switch a light switch or occupancy switch A separate 24V power supply is required if two or more units are being shut...

Страница 18: ...xtend the life of the hoses heat exchangers and other water side accessories WATER FLOW RATE Open all isolation valves to the unit Ensure that the entering and leaving fluid temperatures of the BULLDO...

Страница 19: ...unit Disconnects are usually within reach of the unit Exercise caution at all times Inspect the fan section to ensure that it is clear of any debris and that the fan rotates freely BULLDOG 008 060 uni...

Страница 20: ...LLDOG SideWinder Installation Operation and Maintenance Manual START UP To register the unit warranty proper start up is required by a factory approved technician The following items must be recorded...

Страница 21: ...ed load amps by more than 10 percent of the values noted on the unit nameplate SAFETY CONTROL RESET All BULLDOG Heat Pumps include high and low pressure switches to prevent the machine from operating...