Dual-bus mode configurations
For a dual-bus mode configuration, the SCSI bus split switches must be set to on.
Each 2104 Model TS4 in the configuration is connected either to one external SCSI
connector on an adapter card, or to an integrated SCSI port. If an adapter card has
four external SCSI connectors, it can be connected to up to four 2104 Model TS4.
The external SCSI connectors can be either on the same adapter card, or on two
separate adapter cards. If the connectors are on two separate adapter cards, these
adapter cards can be either in the same host system or be in two separate host
systems.
Appendix B. Cable configurations
35