Buccaneer connectors are available in 2, 3, 4, 6, 7, 9, 12 or 25 pin and BNC

 

coaxial versions (50/75Ω).

It is important that these instructions are fully complied with to ensure the

 

product is completely watertight and electrically safe -
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN.

                          

NEVER UNMATE OR MATE THE PRODUCT WHILE STILL UNDER LOAD

Always wire the socket insert to supply, and the plug insert to appliance.

 

Plug/socket inserts can be fitted into any style of main body to give correct

 

plug/socket combination for your application.

Use smooth circular cable only (6-8mm dia). Other cable glands are available to

suit different cable diameters, please enquire.

ASSEMBLY/WIRING INSTRUCTIONS

1

To remove plug or socket inserts for wiring, use cap assembly tool to

unscrew locking ring.

2

As appropriate to main body type, thread cable through component parts

as shown in the illustrations.

3

Strip insulation from cable as shown in Flex Mounting diagram. 

4

2 to 7 pole inserts:

Insert bare wire ends into terminals on plug/socket insert and fully tighten

screws.

Note: If connector is to be used on mains voltage ensure that wires are

connected as shown below.

9 pole inserts:

Pins and sockets are supplied loose for pre-crimping. Crimping tools

(including hand versions) and a contact extraction device are available.

Please enquire.

12 and 25 pole inserts:

Pins and sockets are supplied loose for pre-crimping and pre-soldering.

Crimping tools (including hand version) and a contact extraction device are

available. Please enquire.

5

After connecting wires, draw cable back until plug/socket insert is correctly

seated in D shaped location in the main body. Screw home locking ring

using cap assembly tool.

6

For cable mounted units, slide gland cage and gland down cable and into

main body then screw gland nut fully home. It is essential to ensure that

the gland nut is fully tightened to ensure cable is securely sealed and

clamped. For panel, bulkhead and flange units correctly seat sealing

washer and main body onto mounting surface and screw down using rear

nut or screw/bolts with seals. Ensure seals and glands are kept clean.

Locking cap secures plug to socket.

Note:

To ensure that the correct sealing properties of the connector are achieved it is

imperative that all ‘O’ rings are correctly located and seated before assembly.

Please refer to the exploded diagrams for the locations of these seals.

Standard Buccaneer Waterproof Electrical Cable Connector

FLEX MOUNTING

FRONT OF PANEL MOUNTING

REAR OF PANEL MOUNTING

LOW PROFILE  FLANGE MOUNTING

BULKHEAD/SURFACE MOUNTING

Mains Wire Connections

Important - connect
wires Brown to terminal
L, Blue to terminal N
and Green/Yellow to
terminal E

For  your  protection  all  mains  (250V)

equipment  used  out  of  doors,  in  damp  or

wet  conditions  should  be  supplied  from  a

correctly fused source and protected by an

approved  R.C.D.  Eg:  BS7071,  BS7288,

BS4293, BSEN61008 or BSIEC1008.

IF IN DOUBT SEEK ADVICE

IMPORTANT SAFETY NOTICE

FLEX MOUNTING IN-LINE

Part No: 13158, issue 8

Wiring and Assembly Instructions