Fluidcontrol

Installation and Operation Instructions

Original instructions

Display and control unit

Thermotronik TT-77

BE140013
07/2019

Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen

Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20

E-Mail: [email protected]

Internet: www.buehler-technologies.com

Содержание Thermotronik TT-77

Страница 1: ...instructions Display and control unit Thermotronik TT 77 BE140013 07 2019 B hler Technologies GmbH Harkortstr 29 D 40880 Ratingen Tel 49 0 21 02 49 89 0 Fax 49 0 21 02 49 89 20 E Mail fluidcontrol bu...

Страница 2: ...ad this instruction carefully prior to installation and or use Pay at tention particularly to all advises and safety instructions to prevent in juries B hler Technologies can not be held responsible f...

Страница 3: ...of the switching characteristic 16 5 7 2 Switching output x Upper switching limit switching point 17 5 7 3 Switching output x Lower switching limit switch back point 18 5 7 4 Switching output x Switc...

Страница 4: ...T 77 9 4 Standard pin assignment TT 77W 32 9 5 Current settings 33 9 6 Display ranges 33 9 7 Menu Sequence Overview 34 9 8 Display resolution 35 10 Attached documents 36 ii B hler Technologies GmbH BE...

Страница 5: ...on the configuration The outputs are freely programmable The available versions are TT77F The display and control unit can be mounted to the tank along with the switching tube TT77W The display and c...

Страница 6: ...s 2 x PNP output 2T K 2T 4 x PNP output 4T 1 x PNP output 1 x analogue output 1T K 2 x PNP output 1 x analogue output 4T K 4 x PNP output 1 x analogue output TT 77F tank mounted version 1 x IO Link 1...

Страница 7: ...This manual is part of the equipment The manufacturer keeps the right to modify specifications without advanced notice Keep this manual for later use Signal words for warnings DANGER Signal word for...

Страница 8: ...ons are observed during disposal compliance with national installation regulations Maintenance Repair Please note during maintenance and repairs Repairs to the unit must be performed by B hler authori...

Страница 9: ...rt the product inside the original packaging or a suitable alternative The equipment must be protected from moisture and heat when not in use It must be stored in a covered dry dust free room at room...

Страница 10: ...into the designated bore on the tank When installed with remote display the display and control unit are mounted to a 35 mm 1 4 top hat rail The sensor connects with a line The connector for the sens...

Страница 11: ...r message appears in the display during operation please refer to the Troubleshooting table under chapter Service and Repair 5 2 LED statuses LEDs above the measurement display indicate the status of...

Страница 12: ...select a menu item and to enter values Open the main menu with the key Select the submenu with the and keys and open the submenu with the key If necessary select the next submenu with the and keys and...

Страница 13: ...Out 1 out_ Settings menu OUTX Out X An 1 Settings menu Analog 1 Analog Out 1 E Exit menu level Exit b EF Basic Adv Functions Basic EF If applicable If applicable DiA Diagnostics menu Diagnostic E Exi...

Страница 14: ...handling and analysis The function Disable error handling Err h is used to disable normal error handling and analysis This may pose dangers to the user or machine Basic EF b EF Basic ext functions Er...

Страница 15: ...1 5 Selection menu Setting range 0 25 to 1 5 Measuring cable cross section for compensating the Pt100 supply line resistance 5 6 5 Define switching outputs Here you can define the switching outputs U...

Страница 16: ...fter entering at least one digit 0 A dot indicates the active digit during this input Setting range 000 to 999 Use the key to open the list of values Enter the digit using the and keys 0 to 9 and pres...

Страница 17: ...pecific specifications the factory preset may vary from those listed here Basic settings Basic Settings t uni C dis FASt Loc 000 tcl 0 0m tcC 0 50II for wall mounting only Version with 1 switching out...

Страница 18: ...ions are Hysteresis Function Hysteresis function as the NO contact Hysteresis function as the NC contact NO contact or NC contact function when the output signal is set when exceeding the configured s...

Страница 19: ...nc Note The designation of the switching function may vary Measured variable 5 7 2 Switching output x Upper switching limit switching point The upper switching limit for switching output Out x can be...

Страница 20: ...easured variable ____ out_ Measured variable main menu Out X EF_ EF X Advanced Functions dS_ Delay SP X Delay OUTX On ___ Selection menu 0 100 Settings menu OUTX Setting range 0 100 seconds Time span...

Страница 21: ...2 switching outputs Assignment for 4 switching outputs 1 LED 1 yellow LED 1 yellow LED 1 yellow 2 LED 2 red LED 2 red 3 LED 3 yellow 4 LED 4 red In the factory setting the LED indicates the physical s...

Страница 22: ...status LEDX L __ Selection menu L o L _o Settings menu OUTX The options are LED output the LED lights up when the PNP switching output is closed LED output the LED lights up when the PNP switching ou...

Страница 23: ...output with different value ranges This is configured in menu Measured variable ____ An_ Measured variable main menu Analog OutX A ou_ Set A OUtX Output function _ _ Selection menu i I u 3 Settings me...

Страница 24: ...last 6 events for the switching output being logged can be viewed here and all entries deleted Diagnostic diA Diagnostics menu J out Log output Journal Out ____ Jor I Selection menu The journal entrie...

Страница 25: ...ing output to be logged Only one switching output can be logged Diagnostic diA Diagnostics menu SJ ou Output monitoring Set Journal Out out_ Out I Out_ Selection menu Options out1 to outx Switching ou...

Страница 26: ...tenance This device is maintenance free The method for cleaning the devices must be adapted to the IP protection class of the devices Do not use cleaners which could damage the device materials 24 B h...

Страница 27: ...eted and signed RMA decontamination statement to the packaging We will otherwise be unable to process your repair order You will find the form in the appendix of these instructions or simply request i...

Страница 28: ...orrect output current Wrong signal type set In submenu Aoux Check and if necessary set the correct signal type current voltage out put Load too high current output Reduce load to permissible value Ana...

Страница 29: ...sposal Dispose of parts so as not to endanger the health or environment Follow the laws in the country of use for disposing of elec tronic components and devices during disposal 27 B hler Technologies...

Страница 30: ...s Current input during operation approx 50 mA without current and switching outputs Supply voltage UB 10 30 V DC nominal voltage 24 V DC with IO Link 18 30 V DC Ambient temperature 20 C to 70 C Displa...

Страница 31: ...with 1 x assignable to alarm logbook with 1 x assignable to alarm logbook max switching current 0 5 A per output continuous short circuit protected Output 1 max 0 2 A Contact load max 1 A total Analo...

Страница 32: ...r 100 ms Current input during operation approx 50 mA without current and switching outputs Supply voltage UB 10 30 V DC nominal voltage 24 V DC with IO Link 18 30 V DC Ambient temperature 20 C to 70 C...

Страница 33: ...4 20 mA 2 10 V DC 0 10 V DC 0 5 V DC Max load as current output UB 8 V 0 02 A UB 8 V 0 02 A UB 8 V 0 02 A Min input load as voltage output 10 k 10 k 10 k also programmable as frequency output Output 1...

Страница 34: ...connection Version 1D1S 2T 1T KT 2T KT 4T 4T KT M12 base 4 pin 4 pin 4 pin 5 pin 8 pin 8 pin Panel plug Pin 1 2 3 4 5 6 7 24 V DC T2 PNP GND C Q IO Link 24 V DC T2 PNP GND T1 PNP 24 V DC Analogue GND...

Страница 35: ...4 rP4 r ou3 ds4 dr4 ou4 r ou4 Di5 Loc Analogue outputs tcl A1 Hi A1 Lo A ou1 tcC A2Hi A2 Lo A ou2 for wall mounting only Date Signature 9 6 Display ranges Name Menu Unit Display Range from with unit R...

Страница 36: ...ction menu n oP Lo ____ Hi Output maximum analogue value Analogue output normal mode ____ Analog Out1 Settings menu Analog 1 An1 ____ Exit Exit menu level E Exit menu level E Exit Sets the maximum ana...

Страница 37: ...100 x 200 0 5 100 x 200 0 5 200 x 500 1 200 x 500 1 500 x 1000 2 500 x 1000 2 1000 x 5 1000 x 5 none non2 2 fixed point numbers Range x Resolution x 5 0 01 5 x 10 0 02 10 x 20 0 05 20 x 50 0 1 50 x 1...

Страница 38: ...Thermotronik TT 77 10 Attached documents Declaration of conformity KX110020 Decontamination statement 36 B hler Technologies GmbH BE140013 07 2019...

Страница 39: ......

Страница 40: ...aminated Ja kontaminiert mit Yes contaminated with explosiv explosive entz ndlich flammable brandf rdernd oxidizing komprimierte Gase compressed gases tzend caustic giftig Lebensgefahr poisonous risk...

Страница 41: ...rsetzen Sie vor der Inbetrieb nahme die Verkabelung wieder in den urspr nglichen Zustand Fragen Sie im Zweifel beim Hersteller nach weiteren Informationen Analysing defective assemblies is an essentia...