Nivotemp NT M-XP
5.6.7 Enable/disable keylock
The keylock can be enabled to prevent unauthorised changes to the device settings.
Basic EF
b.EF
Basic Adv. Functions
Lock
Locks the keys
Lock Device
___
0 - 999
Selection menu
The keylock will be enabled after entering at least one digit > 0. A dot indicates the active digit during this input.
Setting range:
000 to 999
– Use the key to open the list of values:
– Enter the digit using the
and
keys (0 to 9) and press the key to confirm. The active digit
will move one place to the right.
– Lastly, press the key to confirm the code.
The device will now return to the submenu.
Note:
– To disable the keylock enter: 000
5.6.8 Liquid level scaling
The display range is scaled between the highest and lowest float position. This scaling will also affect the display accuracy and
the resolution for determining the switching outputs for the liquid level.
The following illustration shows the factory setting for the switching outputs and the display:
A = factory settings
1 = measuring range
Models with analogue output:
The factory setting for the display is in descending order for increasing liquid level, so the bottom position shows 0 % and the
top position shows 100 %. The values can be switched as described below.
15
Bühler Technologies GmbH
BE100023 ◦ 06/2021