background image

7

UNI-1100 UNI-BUG II  Welding Kit 120 VAC
UNI-1102 UNI-BUG II  Welding Kit 240 VAC
UNI-1104 UNI-BUG II  Welding Kit 42 VAC

Net Weight:

19 lbs. (8.62 kg)

Shipping
Weight:

21 lbs. (9.53 kg)

Includes:
 (1) BUG-1855 UNI-BUG Welding Group
 (1) UNI-100_  UNI-BUG II

UNI-1200 UNI-BUG II Cutting Kit 120 VAC
UNI-1202 UNI-BUG II Cutting Kit 240 VAC
UNI-1204 UNI-BUG II Cutting Kit 42 VAC

Net Weight:

20 lbs. (9.07 kg)

Shipping
Weight:

22 lbs. (10.0 kg)

Includes:
 (1) BUG-1875 UNI-BUG Cutting Group
 (1) UNI-100_  UNI-BUG II

UNI-BUG II KITS

18

PROBLEM

CAUSE

REMEDY

Does not run. Indicator

No input power.

- Turn on the circuit breaker.

light off.

- Plug in the line cord.
- Insure there is power at the outlet.

Broken Wire.

- Unplug the machine from power.

- Examine internally and rewire at

fault.

Bad circuit.

- Replace if breaker has input power

and no output when in the “ON”
position.

Bad travel switch.

- Replace if switch has input power

and no output when ‘ON”.

Does not run. Indicator

Wiring short.

- Unplug the machine from power.

light off and circuit

Examine internally and rewire at

breaker is tripped.

fault.

Burned out part.

- Unplug the machine from power.

Examine internally and replace any
part that looks burned up.

Other.

- Can only be determined by factory

or qualified repair person.

Does not run. Indicator

Bad connection.

- Unplug the machine from power.

light on.

Examine internally and fix any
broken connections.

- Tighten terminal screws on speed

control board.

Open transformer.       - Replace the transformer if there is

input power on the primary and no
output on the secondary.
(12 VAC/CT is expected)

Burned out part.

- Unplug the machine from power.

Examine internally and replace any
part that looks burned up.

Wiring short.

- Unplug the machine from power.

Examine internally and rewire fault.

Failed motor.

- Replace the motor if it has

input voltage and does not turn.

Failed control

- Unplug the machine from power.

card.

Check the card for damaged traces
or parts. Repair or replace if required.

- Verify the card has 12 VAC/CT

input power. Replace the card if the
output to the motor leads is OV
with the speed knob at maximum.

Other.

- Can only be determined by factory or a

qualified repair person.

TROUBLESHOOTING GUIDE

MORE

Содержание UNI-BUG II

Страница 1: ...our equipment identification information below for future reference This information can be found on your machine nameplate Model Number Serial Number Date of Purchase Whenever you request replacement parts or information on this equipment always supply the information you have recorded above LIT UBII IPM 0308 UNI BUG II THE UNIVERSAL BUG O INSTRUCTIONS AND PARTS MANUAL ...

Страница 2: ... injury may result 3 Verify the customer supplied power connections are made in accordance with all applicable local and national electrical safety codes If none exist use International Electric Code IEC 950 4 Never remove or bypass the equipment power cord ground Verity the equip ment is grounded in accordance with all applicable local and national electrical safety codes If none exist use lntern...

Страница 3: ...BUG II 10 EXPLODED VIEW PARTS LIST BUG 1875 UNI BUG CUTTING GROUP 11 EXPLODED VIEW PARTS LIST BUG 1856 UNI BUG WELDING GROUP 12 WIRING DIAGRAM ELECTRICAL COMPONENT CHART 13 EXPLODED VIEW PARTS LIST BUG 1795 COMPACT CORNER FOLLOWER 15 EXPLODED VIEW PARTS LIST UNI 1350 UNI BUG DUAL WELDING 14 UNI BUG II FOR DUAL WELDING RACKMOUNTING UNI 1019 GROUP 16 UNI BUG BULB FLAT WELDER 17 UNI BUG II WITH STITC...

Страница 4: ... allows for easy mounting and removal at any point along the workpiece The UNI BUG II can weld or cut both straight line and on an inner radius as small as 6 152 mm It will travel at speeds of 4 75 ipm 102 1905 mm min with a 50 lb 22 7 kg horizontal pulling capacity The UNI BUG II is designed to run on the edge of a bar or stiffener up to 2 50 8 mm thick as shown below Front and rear rollers suppo...

Страница 5: ... switch to ON 7 Turn on the weld contactor switch to begin welding FEATURES Support roller Idler screw knob to engage idler wheels Front motor drive wheel to move UNI BUG II Front idler wheel Bracket that holds idler wheels SET UP 20 WARRANTY FOR A PERIOD OF TWELVE 12 MONTHS FROM DELIVERY BUG O SYSTEMS WARRANTS TO THE ORIGINAL PURCHASER DOES NOT INCLUDE AUTHORIZED DISTRIBUTORS THAT A NEW MACHINE I...

Страница 6: ...oard Replace the card Failed speed Replace if visually appears damaged potentiometer Verify no loose or broken connec tions to the part Unit runs but erratic Poor input voltage Verify the machine power source is or poor speed control regulation stable and at the correct voltage Measure at the outlet Faulty control Unplug the machine from power card Verify there are no bad connections to the contro...

Страница 7: ...ght off and circuit Examine internally and rewire at breaker is tripped fault Burned out part Unplug the machine from power Examine internally and replace any part that looks burned up Other Can only be determined by factory or qualified repair person Does not run Indicator Bad connection Unplug the machine from power light on Examine internally and fix any broken connections Tighten terminal scre...

Страница 8: ... Fit Hd Soc Scr 1 4 20 x 3 4 43 4 FAS 1305 Hex Nut 4 40 44 3 FAS 1320 Hex Nut 8 32 45 1 FAS 1445 Si Pan Hd Th Rolling 10 32 x 1 2 46 4 FAS 2824 Fit Hd Sit Scr 8 32 x 1 3 4 47 1 MUG 1192 Rotary Switch w Knob 4P 3 Pos 48 1 UNI 1016 Cover 49 1 UNI 1017 Left Side Panel 50 1 UNI 1018 Right Side Panel 51 1 UNI 1021 Base Plate 52 2 UNI 1022 Slave Shaft 53 2 UNI 1023 Bearing 5 8 OD x 1 2 ID x 1 4 Thk 54 2...

Страница 9: ... 60 61 58 59 39 14 19 13 19 10 11 64 16 UNI BUGBULBFLATWELDER Dimensions of machine without torch mounts Torch mounts shown on earlier pages The UNI 1305 Bulb Flat Welder Adaptor Kit can be used with the standard UNI BUG for bulb flat welding Spacer Block For 280 to 430 mm UNI BUG Bulb Flat Welder will weld large bulb angles from 140 430 mm 7 62 194 mm 6 25 159 mm 10 50 267 mm 6 00 152 mm 2 00 51 ...

Страница 10: ...ING GROUP 8 2 7 4 1 3 6 9 5 15 EXPLODED VIEW PARTS LIST UNI 1350 UNI BUG DUAL WELDING GROUP Converts a standard UNI 1000 into a dual welder ITEM QTY PART NO DESCRIPTION 1 4 BUG 1853 Machined Rack 7 1 2 2 1 BUG 1881 Cable Anchor w Swivel Clamp 3 1 BUG 1891 Double Racker Mounting Angle includes 2 of item 4 4 4 FAS 0557 Soc Hd Cap Scr 1 4 20 x 3 4 5 2 BUG 2708 Clamp 6 2 BUG 5451 3 5 Rackholder 7 2 BU...

Страница 11: ... angle clamp block is attached allowing for an additional rackholder and 7 1 2 rack to be mounted vertically At the end of each vertical rack a swivel clamp assembly and torch clamp are added A cable anchor with swivel clamp is mounted to the front right side of the UNI BUG II to complete the set up UNI BUGIIFORDUALWELDING A UNI BUG II converted for dual welding using a UNI 1350 UNI BUG Dual Weldi...

Страница 12: ...BUG 2933 2A PC Power Cord BUG 9445 GOF 3115 BUG 9442 PL Pilot Light BUG 1415 BUG 1428 BUG 1427 T Transformer BUG 9675 GOF 3112 BUG 1466 VT Volt Trap BUG 1393 BUG 1563 BUG 1393 120 VAC PART NO 42 VAC PART NO 240 VAC PART NO UNI 1000 UNI 1002 UNI 1004 13 The UNI BUG II can be used for making fillet welds with the addition of a BUG 1795 Compact Corner Follower shown at right ITEM QTY PART NO DESCRIPT...

Страница 13: ...BUG 2933 2A PC Power Cord BUG 9445 GOF 3115 BUG 9442 PL Pilot Light BUG 1415 BUG 1428 BUG 1427 T Transformer BUG 9675 GOF 3112 BUG 1466 VT Volt Trap BUG 1393 BUG 1563 BUG 1393 120 VAC PART NO 42 VAC PART NO 240 VAC PART NO UNI 1000 UNI 1002 UNI 1004 13 The UNI BUG II can be used for making fillet welds with the addition of a BUG 1795 Compact Corner Follower shown at right ITEM QTY PART NO DESCRIPT...

Страница 14: ... angle clamp block is attached allowing for an additional rackholder and 7 1 2 rack to be mounted vertically At the end of each vertical rack a swivel clamp assembly and torch clamp are added A cable anchor with swivel clamp is mounted to the front right side of the UNI BUG II to complete the set up UNI BUGIIFORDUALWELDING A UNI BUG II converted for dual welding using a UNI 1350 UNI BUG Dual Weldi...

Страница 15: ...ING GROUP 8 2 7 4 1 3 6 9 5 15 EXPLODED VIEW PARTS LIST UNI 1350 UNI BUG DUAL WELDING GROUP Converts a standard UNI 1000 into a dual welder ITEM QTY PART NO DESCRIPTION 1 4 BUG 1853 Machined Rack 7 1 2 2 1 BUG 1881 Cable Anchor w Swivel Clamp 3 1 BUG 1891 Double Racker Mounting Angle includes 2 of item 4 4 4 FAS 0557 Soc Hd Cap Scr 1 4 20 x 3 4 5 2 BUG 2708 Clamp 6 2 BUG 5451 3 5 Rackholder 7 2 BU...

Страница 16: ... 60 61 58 59 39 14 19 13 19 10 11 64 16 UNI BUGBULBFLATWELDER Dimensions of machine without torch mounts Torch mounts shown on earlier pages The UNI 1305 Bulb Flat Welder Adaptor Kit can be used with the standard UNI BUG for bulb flat welding Spacer Block For 280 to 430 mm UNI BUG Bulb Flat Welder will weld large bulb angles from 140 430 mm 7 62 194 mm 6 25 159 mm 10 50 267 mm 6 00 152 mm 2 00 51 ...

Страница 17: ... Fit Hd Soc Scr 1 4 20 x 3 4 43 4 FAS 1305 Hex Nut 4 40 44 3 FAS 1320 Hex Nut 8 32 45 1 FAS 1445 Si Pan Hd Th Rolling 10 32 x 1 2 46 4 FAS 2824 Fit Hd Sit Scr 8 32 x 1 3 4 47 1 MUG 1192 Rotary Switch w Knob 4P 3 Pos 48 1 UNI 1016 Cover 49 1 UNI 1017 Left Side Panel 50 1 UNI 1018 Right Side Panel 51 1 UNI 1021 Base Plate 52 2 UNI 1022 Slave Shaft 53 2 UNI 1023 Bearing 5 8 OD x 1 2 ID x 1 4 Thk 54 2...

Страница 18: ...ght off and circuit Examine internally and rewire at breaker is tripped fault Burned out part Unplug the machine from power Examine internally and replace any part that looks burned up Other Can only be determined by factory or qualified repair person Does not run Indicator Bad connection Unplug the machine from power light on Examine internally and fix any broken connections Tighten terminal scre...

Страница 19: ...oard Replace the card Failed speed Replace if visually appears damaged potentiometer Verify no loose or broken connec tions to the part Unit runs but erratic Poor input voltage Verify the machine power source is or poor speed control regulation stable and at the correct voltage Measure at the outlet Faulty control Unplug the machine from power card Verify there are no bad connections to the contro...

Страница 20: ... switch to ON 7 Turn on the weld contactor switch to begin welding FEATURES Support roller Idler screw knob to engage idler wheels Front motor drive wheel to move UNI BUG II Front idler wheel Bracket that holds idler wheels SET UP 20 WARRANTY FOR A PERIOD OF TWELVE 12 MONTHS FROM DELIVERY BUG O SYSTEMS WARRANTS TO THE ORIGINAL PURCHASER DOES NOT INCLUDE AUTHORIZED DISTRIBUTORS THAT A NEW MACHINE I...

Страница 21: ... allows for easy mounting and removal at any point along the workpiece The UNI BUG II can weld or cut both straight line and on an inner radius as small as 6 152 mm It will travel at speeds of 4 75 ipm 102 1905 mm min with a 50 lb 22 7 kg horizontal pulling capacity The UNI BUG II is designed to run on the edge of a bar or stiffener up to 2 50 8 mm thick as shown below Front and rear rollers suppo...

Отзывы: