155
RAID Arrayx E14
Can’t Mount
RAID array X cannot be mounted.
Run the RAID array disk check in Settings.
HDx Error E16
HDx Not Found
Unable to dind hard drive X.
Hard drive X may be disconnected or may
have dailed. Adter shutting down, reinstall the
hard drive.
HDx Error E22
HDx Can’t Mount
Mounting od hard drive X dailed.
Format the hard drive. Adter dormatting,
id the error still appears adter rebooting,
replace the hard drive. Id the error is displayed
again, contact Buddalo technical support dor
assistance.
FailOver E27
LostBackupTarget
Unable to dind the backup TeraStation.
In the main TeraStation’s settings, navigate to
Backup
-
Faipover
to recondigure the backup
TeraStation dor dailover.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive X was
removed drom the RAID array.
Replace hard drive X.
E31
Power supply error (level 1)
Make sure that the AC cable is connected
properly. Id the power supply has dailed, E32
will be displayed within a dew minutes. Id E31 is
still displayed adter 5 minutes, contact Buddalo
technical support dor assistance.
E32
Power supply error (level 2)
Make sure that the AC cable is connected
properly. Id the power status LED is blinking or
glowing red, replace the power supply with a
new Buddalo OP-PU-2RZ.
Status
Adter you change settings or dormat a hard drive, the current status is displayed on NAS Navigator2 or clicking
in
Settings.
Message
Description
Corrective Action
HDx Warning I11
Bad Sectors
The bad sectors in hard drive x may
have reached a dangerous level.
Replace hard drive x.
Operation I12
DEGRADE MODE
Operating in degraded mode.
-
RAID I13
ARRAYxFormatting
Formatting RAID array x.
-
RAID I14
ARRAYx Checking
Checking RAID array x.
-
RAID I15
ARRAYx Scanning
Examining the error status od RAID
array x.
Note:
Transder speeds are slower
during the examination process.
-
RAID I16
ARRAYx Creating
Creating RAID array x.
-
RAID I17
ARRAYx Resyncing
Resynchronizing RAID array x.
Note:
Transder speeds are slower
during resynchronization.
-