RAID 1
Combines 2 or more drives into a mirrored array. The available space in the array is the capacity of a single drive.
Identical data is written to each drive. If a drive is damaged, data can be recovered by replacing the damaged drive.
As long as one drive in the array remains undamaged, all data in the array can be recovered.
RAID 0
Combines 2 or more drives into a single array. The usable drive space is the total space of all drives used. This simple
RAID mode offers faster performance than RAID modes that include parity. If a single drive in the array fails, then all
data in the array is lost.
JBOD
This mode uses the drives inside the TeraStation as individual drives. The drive space you can use is the total
capacity of all drives in the TeraStation. If any drive is damaged, then the data on that drive is lost.
Working with RAID Arrays
To change RAID settings, navigate to
Storage
-
RAID
in Settings.
Using JBOD
With JBOD, each drive in the TeraStation is addressed separately. To put drives from an array into JBOD, follow the
procedure below.
1
In Settings, click
Storage
.
2
Click
to the right of "RAID".
3
Click the array to delete.
Содержание TeraStation 5010
Страница 8: ...7 For Customers in Taiwan 175 ...
Страница 67: ...66 1 In Settings click Backup 2 Click to the right of Backup 3 Click List of LinkStations and TeraStations ...
Страница 75: ...74 3 Click Edit 4 Click Add 5 Click Browse under Replication Source ...
Страница 87: ...86 18Click Time Machine ...
Страница 88: ...87 19Click Select Backup Disk 20Select the TeraStation then click Use Disk ...
Страница 97: ...96 3 Click Create New Job 4 Select backup settings such as date and time to run 5 Click Add ...
Страница 103: ...102 4 Click the Options tab 5 Click Edit ...
Страница 114: ...113 7 Move the NFS switch to the position to enable NFS 8 Click to the right of NFS 9 Click the Client Settings tab ...
Страница 128: ...127 Updating Automatically 1 In Settings click Management 2 Click to the right of Update 3 Click Edit ...
Страница 137: ...136 3 Click Edit ...
Страница 138: ...137 4 Select or enter the desired MTU size and click OK ...
Страница 140: ...139 3 Click Edit 4 Clear the DHCP checkbox and enter the desired IP address and its subnet mask ...