GEN1850 Troubleshooting Frequently Asked Questions

Download Complete Product Manual/Parts List 

HERE

Read and review all Warning labels on product and all Warning instructions in manual before operating generator.

Do not run the generator if you do not understand how to use it.

WARNING: NEVER use a generator inside a home or a garage, EVEN IF the doors and windows are open. 

ONLY USE OUTSIDE and far way from windows, doors and vents leading into an enclosed area. 

Using a generator indoors can kill you in minutes. The generator produces an exhaust that contains carbon monoxide.

This is a poison you cannot see or smell. 

Do not attach a chain or rope to secure the generator to a post as this can be difficult to remove in the event of an emergency.

Specifications

• 2.8 HP OHV Engine

• Recoil Start

• Gasoline Engine

• 2 - 120 Volt A/C Outlets

• 1 - 12 Volt D/C Outlet

• 120 Volt/ 15A / 60 Hz

• EPA Approved

• 3,600 RPM / Single Phase

• Engine Run Time: 11 Hours @ 50% Load

• Oil Type: SAE10W-30 Oil (Must add BEFORE first use)

• Oil Capacity: 13.5 fluid oz (0.40 L)

• Fuel Type: Unleaded gasoline octane rating of 87 or higher

• Fuel Capacity: 2.3 Gallon Fuel Tank

• Spark Plug: E6TC spark plug included

(Comparable: Bosch W7BC, Champion L92YC, NGK BP6HS)

• Battery: Not Required (this is Recoil Start Only)

• Mobility Kit: This model is not designed to include Mobility Kit

• Warranty: 90 day limited

Using My Generator

- How do I prepare my generator for use?

- Where should I set up my generator?

- How do I start my generator?

- How do I plug devices into my generator?

- Can I connect my generator to my house?

- What can safely be plugged into my generator?

- How do I stop my generator?

Generator Care & Maintenance

- How do I clean the carburetor?

- How do I clean & care for my generator?

- How often should the oil be changed?

Содержание GEN1850

Страница 1: ...cations 2 8 HP OHV Engine Recoil Start Gasoline Engine 2 120 Volt A C Outlets 1 12 Volt D C Outlet 120 Volt 15A 60 Hz EPA Approved 3 600 RPM Single Phase Engine Run Time 11 Hours 50 Load Oil Type SAE1...

Страница 2: ...Be careful not to fill the fuel tank above the upper limit line The fuel tank capacity for this generator is 1 8 gallon 7 L NOTE Because gasoline can expand DO NOT fill the fuel tank to the very top S...

Страница 3: ...operly ground this generator can result in electrocution Ground this generator by tightening the grounding nut against a grounding wire A generally acceptable grounding wire is a No 12 AWG American Wi...

Страница 4: ...ire to the positive terminal of the battery and the other charging wire to the negative terminal of the battery Connect the free end of the positive wire to the positive side of the outlet on this gen...

Страница 5: ...essential for safe economical and trouble free operation It will help prolong the life of this generator as well as help reduce air pollution Perform maintenance checks and procedures according to th...

Страница 6: ...st 2 minutes before removing the fuel tank cap Loosen the cap slowly to relieve pressure in the fuel tank To ensure that this generator runs smoothly use only FRESH UNLEADED GASOLINE WITH AN OCTANE RA...

Страница 7: ...rburetor cleaner on the float needle or any of the rubber gaskets Gas may not be getting to the carburetor Remove the carburetor and turn the drain screw counter clockwise DO NOT completely remove the...