background image

 

Gas Fryer

 

 

Installation and Operation Instructions

 

 

 

 

 

 

Model: DC319-P, DC319-N 

 

IMPORTANT FOR FUTURE REFERENCE 

Please complete this information and retain this manual for the life of the equipment. For War-
ranty Service and/or parts, this information is required. 
 

   

 

 

 

 

Model Number                      

Serial Number                    

 

Date Purchased 

 

 

WARNING:

 For your safety, do not store or use gasoline or other flammable vapors or  

liquids in the vicinity of this or any other appliances. Keep the area free and clear of  

combustible materials.  

 
 

WARNING

Improper installation, adjustment, alteration, service or maintenance can  

cause property damage, injury, or death. Read the installation operating  and mainte-
nance instructions thoroughly before installing, or servicing this equipment.

 

 

 

WARNING

Instructions must be posted in a prominent location. All safety precautions 

must be taken in the event the user smells gas. Safety information can be obtained from 

your local gas supplier. 

 

 

WARNING

Components must not be cleaned in a dishwasher 

 

 
 
 

 

 

 

 

 

 

 

 

 

                                                       

Nisbets PLC  

Fourth Way, Avonmouth, Bristol, BS11 8TB,

 

Unit 9003, Blarney Business Park, Blarney, Co. Cork 

 

 

 

Содержание DC319-N

Страница 1: ...ep the area free and clear of combustible materials WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating...

Страница 2: ...rances Assembly Gas Connection Commissioning Operation 10 Operation Guide Filling the Fryer Pot Shutdown Procedure Relighting Automatic Pilot Valve High Limit Control Cleaning and Maintenance 13 Routi...

Страница 3: ...STRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL...

Страница 4: ...Natural Gas G20 Propane G31 Butane G30 Models DC319 N DC319 P DC319 P Single burner Heat Input 8 8KW 8 8KW 8 8KW Heat Total 26 4 KW 26 4 KW 26 4 KW Manifold Pressure 17 mbar 36 mbar 29 mbar Min Inlet...

Страница 5: ...5 Dimensions DC319 P DC319 N...

Страница 6: ...adjusted by an authorized service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic...

Страница 7: ...bled before delivery except castors This appliance is fitted with castors to enable the appliance to be positioned securely and level This should be carried out on completion of the gas connection Ref...

Страница 8: ...outdoors in accordance with local codes or in the absence of local codes with the United Kingdom Gas Safety Installation and Use Regulations 1998 BS 6173 Installation of Catering Appliances BS 5440 1...

Страница 9: ...ch edge Commissioning 1 Before leaving the new installation a Check the following functions in accordance with the operating instructions specified in the Operation section of this manual Light the Pi...

Страница 10: ...conds before repeating the lighting procedure and keep the Operating knob down longer Adjustment of pilot flame may be necessary 2 After the gas is alight turn Operating knob to ON position Note By tu...

Страница 11: ...be added until the desired frying depth has been reached 8 Replace the basket support frame over the fryer pot heat tubes Shutdown Procedure Standby Turn Operating Knob on the combination gas valve t...

Страница 12: ...IS SPACE All burners are lit from constantly burning pilots Turning the valve to the desired is all that is required to put the unit in service Do not permit fans to blow directly at the unit Wherever...

Страница 13: ...he fryer pot with a little hot oil 4 Wipe off the basket support frame and the inside of the fryer pot with a clean cloth CAUTION SOME AREAS OF THE FRY POT MAY BE HOT 5 Close drain valve and strain th...

Страница 14: ...e procedure can usually be removed by rubbing the surface with scouring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil...

Страница 15: ...ble advice or other assistance and for genuine factory parts All units are adjusted at the factory In case of problems in operation at initial installation check type of gas and manifold pressure and...

Страница 16: ...tor Thermocouple connection to the gas control is loose or faulty Thermocouple faulty Electromagnet in the rear of the gas control unit is faulty Hold knob in for at least 20 sec onds following igniti...

Страница 17: ...17 Explosion drawing DC319 P DC319 N 1 3 4 5 7 8 6 9 10 2 12 13 16 11 15 17 18 19 21 20 22 23 24 25 14 26 27...

Страница 18: ...1071045 Pilot pipe 1 13 01 05 1031379 Stand 1 14 01 02 1005319 Universal Wheel brake 1 15 03 99 1290238 High Temperature Protector 1 16 01 05 1031167 Solenoid Electric Valve Fix Plate 1 17 06 05 1473...

Страница 19: ...gas supply at the mains supply 2 Remove the mirror plate 3 Unscrew the burner screws and take all the burners out 4 Remove the Main Injector for Determine the correct Orifice size for the new gas type...

Страница 20: ...pilot burner 3 Determine the correct injector size for the corresponding gas from the rating label 4 Re connect the supply tube to the base of the pilot burner and tighten the gas supply tube at the g...

Страница 21: ...21 Replace Flame distributor Gas Type Identification Label On completion of the gas conversion replace the gas type identification label located on the right hand panel For NG For LPG...

Страница 22: ...nsure that all the controls operate correctly Ensure that the operating pressure remains correct 3 Ensure any adjustments done to components that have the adjustments settings sealed e g paint sealed...