background image

TM

User Manual

BS-GU2008

Package Contents

The package contains the items shown below. If any items are missing, 
please contact the dealer where you purchased the BS-GU2008 .
The appearance of the BS-GU2008 may vary from the illustration.

•  Switch (main unit) ...................................................................................................... 1
•  Power cable .................................................................................................................. 1
•  Rubber feet .................................................................................................................. 4
•  Serial number stickers ............................................................................................. 2
•  User manual (this document) ................................................................................. 1
•  Warranty  ........................................................................................................................ 1

Layout

1.Indicators

Indicators are located on the front panel of the product. The functions of 
each indicator are shown below.

 

Link/Act (Green)

 

On: 

Link established

 

Blinking:  Data transfer

 

Blinking (1-second interval):  Loop detected

 

Off: 

Link not established

 

1000/100/10M (Green or Orange)

 

On (Green):  1000 Mbps link

 

On (Orange):  100 Mbps link

 

Blinking (Green or Orange):  Loop detected

 

Off: 

10 Mbps link or no link

 

Loop (Red)

 

Blinking:  Loop detected

 

Off: 

Normal

 

Power (Green)

 

On:  Power on

 

Off:  Power off

2. Loop detection switch

Switch loop detection on and off.

3. LAN ports

These are ports for connecting 1000BASET/100BASE-TX/10BASE-T devices.

4.Power connector

Connect the included power cable to this connector.

Loop Detection

This unit can detect network loops that can cause interference in the 
network.

What Is a Loop?

If both ends of an Ethernet cable are connected to the same hub, or when 

multiple connections exist between two hubs, data may be sent in a loop 
around the network, wasting network capacity and never getting to its 
destination. This continuously circulating data may interfere with other 
network communication.

Loop Detection

・Off: 

Loops are not detected.

・On: 

If a network loop is detected, the link/act, 1000/100/10M, and loop 

LED on the front of this unit blink once per second.

Turning Loop Detection On and Off

1.

 Use the switch on the front of the BS-GU2008 to turn loop detection on and 

off.

2. Disconnect the power cable, then reconnect it.

Note: The setting isn't changed until power cable is disconnected and 

reconnected.

Caution : 

 While loop detection is enabled, the BS-GU2008 will send a loop 

detection packet through the network every two seconds. If these 
packets disrupt your network in any way, disable loop detection.

 Loop detection cannot detect or block all types of loops.

When a Loop is Detected

Reconnect the wiring, making sure that no wires are connected in a

loop.

Precautions for Installation

•  Do not install the device in an unstable location such as on an unsteady 

table or an inclined surface.

•  Do not place another hub or object that generates heat on top of this 

unit.

•  Please route all cables properly to prevent people from tripping over 

them.

•  Ensure the air vents on the product are not blocked by other equipment 

or walls.

•  Only use the power cable included with the product. Using other power 

cables may result in damage or fire.

Floor or Shelf Mounting

Attach the supplied rubber feet to the bottom corners of the unit before

use.

Mounting to a Metal Surface

To mount to a metal surface, such as the side of a steel desk, use the 

"BS-MGK-A Magnet Kit" (sold separately). Attach the supplied rubber feet to 

the bottom corners of the unit before using the magnet kit.

Caution: 

・ 

Do not put floppy discs, magnetic cards, or other magnetic storage 
media near magnets. Doing so may delete or corrupt data.

・ 

If the switch is secured by the magnet alone, it should be no more than 

75 cm (29.5 in) from the floor.

Mounting to a Wall

To mount the unit to a wall, use 2 screws (not included) with the dimensions 
shown below. Install the screws 78 mm (3.1 in) apart and slide the mounting 

holes in the base of the BS-GU2008 over them.

Installation

Use screws where this section is 

2 mm (0.08 in) or less.

φ6 mm (0.24 in)

2 mm (0.08 in)

3mm (0.12 in)

1.  Indicators

2.  Loop detection switch

4.  Power connector

3.  LAN ports