2
Product Information
Logalux LT160/1 | LT200/1 | LT300/1 – 6 720 811 745 (2021/10)
5
2
Product Information
2.1
Scope of delivery
• DHW tanks
• Installation and Maintenance Instructions
• B-KIT
Fig. 1
B-kit
[1]
Tee 1" x 1" x ¾ "
[2]
Temperature and pressure relief valve
[3]
Cap ¾ "
[4]
Drain valve
[5]
Tee 1¼ " x 1" x ¾ "
[6]
Sensor Well
[7]
Coupling ¾ "
2.2
Designated use
The tank is designed for heating and storing drinking water. Please
observe national, regional, and local codes, regulations, guidelines and
standards for drinking water.
Install this tank only in sealed unvented hydronic heating systems.
Any other purpose is considered improper use. Any resulting damage is
excluded from the manufacturer's warranty.
Requirements
for potable water
Unit
Water hardness
ppm
grain/US gallon
°dH
36
2.1
2
pH value
6.5...
9.5
Conductivity
μS/cm
130...
1500
Table 3 Requirements for potable water