16
Installation and maintenance instructions Logalux ST400/3, 500/3, 750/3 and 1000/3 "US" • Issue 07/2005
We reserve the right to make any changes due to technical
Maintenance
8
z
Remove hexagon bolts (Fig. 16,
Item 1
) from the
manual access cover (Fig. 16,
Item 3
).
z
Remove the access cover, transport handle (Fig. 16,
Item 2
) and access cover gasket (Fig. 16,
Item 4
)
from the DHW tank.
8.2
Cleaning the DHW tank
z
Check the DHW tank interior for scale deposits
(calcium).
Should scale deposits be discovered inside the DHW
tank, proceed as follows:
z
Hose down the interior of the DHW tank with a "hard"
cold water jet (approx. 58 –
72 psi pressure)
(Fig. 17).
You can increase the cleaning effect of the jet by
heating up the DHW tank before cleaning. The
thermo-shock effect releases scale deposits more
easily from the coil type heat exchanger. Remove the
residues with a wet & dry vacuum cleaner with plastic
suction tube or flush debris through the tank drain.
Fig. 16
Removing the access cover
Item 1:
Hexagon bolts
Item 2:
Transport handle
Item 3:
Hand hole cover
Item 4:
Manual access cover gasket
Item 5:
Magnesium anode
3
2
1
4
5
CAUTION!
SYSTEM DAMAGE
through damaged surface finish.
z
Never use hard objects or objects with
sharp edges to clean the interior walls
of the DHW tank.
Fig. 17
Hosing down the inside of the DHW tank