background image

1

 

Explanation of symbols and safety instructions

Logano plus – 6720865368 (2019/05)

3

1.2

General safety instructions

H

Instructions for the target group

These operating instructions are intended for the 
heating system user.

All instructions must be observed. Failure to comply 
with instructions may result in material damage and 
personal injury, including possible loss of life.

▶ Read and retain the operating instructions (heat 

source, heating controller, etc.) prior to operation.

▶ Observe the safety instructions and warnings.

H

Safety of electrical devices for domestic use 
and similar purposes

The following requirements apply in accordance with 
EN 60335-1 in order to prevent hazards from 
occurring when using electrical appliances:

“This appliance can be used by children of 8 years and 
older, as well as by people with reduced physical, 
sensory or mental capabilities or lacking in experience 
and knowledge, if they are supervised and have been 
given instruction in the safe use of the appliance and 
understand the resulting dangers. Children shall not 
play with the appliance. Cleaning and user 
maintenance must not be performed by children 
without supervision.”

“If the power cable is damaged, it must be replaced by 
the manufacturer, its customer service department or 
a similarly qualified person, so that risks are avoided.”

H

Danger through failure to consider your own 
safety in an emergency such as a fire

▶ Never put yourself at risk of fatal injury. Your own 

safety is paramount.

H

If you smell gas

▶ Close gas isolator.
▶ Open windows and doors
▶ Never operate electrical switches, including 

telephones, plugs or doorbells.

▶ Extinguish any naked flames. Do not smoke! Never 

use any lighters or sources of ignition of any kind!

▶ Warn all occupants in the building, but do not ring 

doorbells.

▶ If you can actually hear gas escaping, leave the 

building immediately. Prevent third parties from 
entering and notify police and fire brigade 

from 

outside

 the building.

From outside 

the building, call your gas supplier 

and licensed contractor.

H

Danger if you smell flue gas

▶ Switch off the boiler.
▶ Open windows and doors.
▶ Notify an approved contractor.

H

Danger to life from carbon monoxide

Carbon monoxide (CO) is a poisonous gas, which 
arises during the incomplete combustion of fossil fuels 
such as oil, gas or solid fuels. 

Dangers arise, if carbon monoxide escapes from the 
heating system due to a fault or a leak and collects 
unnoticed in enclosed spaces.

You can neither see, taste nor smell carbon monoxide.

To avoid danger from carbon monoxide:
▶ Have the heating system inspected and serviced 

regularly by an approved contractor.

▶ Use a CO detector, which gives an alarm in good 

time if CO escapes.

▶ If you suspect a CO leak:

– Warn your neighbours and leave the building 

immediately.

– Call an approved contractor.
– Have any defects rectified.

H

Installation and conversion

▶ Correct and proper installation and adjustment of 

the burner and the control unit are the fundamental 
requirements for safe and economical operation of 
the floor standing boiler.

▶ Only permit an authorised contractor to install the 

boiler.

▶ Never modify any parts for flue gas routing.
▶ Electrical work must only be carried out by qualified 

electricians.

▶ With 

open-flue mode:

 do not cover or reduce the 

size of ventilation apertures in doors, windows or 
walls. If draught-proof windows are fitted, ensure 
there is an adequate supply of combustion air.

▶ Use the DHW cylinder exclusively for heating hot 

water.

Never shut off pressure relief valves!

Water may be expelled at the pressure relief valve of 
the heating circuit and DHW pipework during heat-
up.

Содержание 7736603544

Страница 1: ...Read carefully prior to operation 6720865368 2019 05 GB Operating instructions for users Gas fired condensing boiler Logano plus 0010018644 002 GB402 395 620 ...

Страница 2: ...d safety instructions 2 1 1 Explanation of symbols 2 1 2 General safety instructions 3 2 Product Information 5 2 1 Declaration of Conformity 5 2 2 Water quality fill and top up water 5 2 3 Product overview 5 2 3 1 Product information 5 3 Commissioning 7 3 1 Checking the operating pressure topping up the heating water and venting the system 7 3 1 1 Checking the operating pressure 7 3 1 2 Topping up...

Страница 3: ... sources of ignition of any kind Warn all occupants in the building but do not ring doorbells If you can actually hear gas escaping leave the building immediately Prevent third parties from entering and notify police and fire brigade from outside the building From outside the building call your gas supplier and licensed contractor H Danger if you smell flue gas Switch off the boiler Open windows a...

Страница 4: ...ed danger H Danger of water damage Intheeventofsevereriskofflooding shutdownthe power and fuel supply to the device before water enters the installation location Never use the device if any part of it has been under water Immediately get in touch with a qualified service technician to have the device inspected and have any part of the control system and any air gas ratio control valves that have b...

Страница 5: ...nger 2 3 1 Product information The main components of the Logano plus GB402 are Control unit not included in scope of delivery Boiler block Appliance frame and casing Gas burner The control unit monitors and controls all electrical components of the floor standing boiler The boiler block transfers the heat generated by the burner to the heating water The thermal insulation reduces the radiation an...

Страница 6: ...front panel 2 Air gas ratio control valve 3 Control unit shown for illustration purposes Logamatic 5313or 8313 4 Gas burner with burner rod 5 Boiler block with thermal insulation 6 Boiler casing 7 Differential pressure switch 8 Condensation catch pan and siphon 9 Burner control unit 0010018751 001 1 2 3 4 5 6 8 9 7 ...

Страница 7: ...sses When topping up a hot boiler with cold heating water thermal stresses can lead to cracking due to internal stress Only fill the heating system when cold Maximum flow temperature 40 C NOTICE System damage due to frequent topping up If you have to top up the heating water frequently the heating system maysufferdamagethroughcorrosionorscaling dependingonthewater quality Ask a certified heating c...

Страница 8: ... maintain a high level of efficiency and to operate the heating system economically low fuel consumption To achieve a high level of operational reliability To maintain the cleanest possible combustion NOTICE Material damage due to a lack of or incorrect cleaning and service Have the heating system inspected maintained and cleaned once a year by a certified heating contractor We recommend you enter...

Страница 9: ...c devices that are no longer serviceable must be collected separately and sent for environmentallycompatiblerecycling inaccordancewith the European Waste Electrical and Electronic Equipment Directive To dispose of old electrical or electronic devices you should use the return and collection systems put in place in the country concerned Batteries must not be disposed together with your household wa...

Страница 10: ......

Страница 11: ......

Страница 12: ...Buderus Cotswold Way Warndon Worcester WR4 9SW All Enquiries 0330 123 3004 www buderus co uk In the UK and IE Buderus is a brand name of Bosch Thermotechnology Ltd ...

Отзывы: