Installation
1
Installation and maintenance instructions for Buderus 500 - 24/S • 08/2006
7
Subject to modifications resulting from technical improvements!
Buderus • http://www.buderus-domestic.co.uk
1
Installation
1.1
Technical specifications
Dimensions
Unit
500 Series wall-mounted condensing gas
system boiler
500 - 24/S
Type of gas supply as established in
EN 437 (GB/IE)
GB/IE II
2H3P
20 mbar, 37 mbar
(natural gas
H
and LPG)
Rated thermal load for heating
Rated thermal load for preparing hot water
kW
kW
5.7 - 23.0
5.7 - 28.5
Rated heating capacity for system temperature (modulating
from 30° to 100°)
Heating curve 75/60
°
C
Heating curve 40/30
°
C
kW
kW
5.3 - 22.0
6.0 - 24.0
Seasonal efficiency (SEDBUK)
for natural gas
for LPG
%
%
90.3
92.3
Max. gas rate for heating
Max. gas rate preparing hot water
m
3
/h
m
3
/h
3.02
2.43
Central heating installation
Heating water temperature
°C
30 - 80
Δ
T at residual head of 200 mbar
°C
< 20
Max. operating pressure of boiler
bar
3.0
Pump over run time
min
5
Expansion vessel
Capacity of expansion vessel
l
7.5
Admission pressure of expansion vessel
bar
1.0
Pipe connections
Gas on installation frame (compression fitting)
Ø mm
22
CH flow/return (compression fitting)
Ø mm
22
MCW inlet / DHW outlet (compression fitting)
Ø mm
15
Condensate water outlet
Ø inch
1
Pressure relief valve (compression fitting)
Ø mm
15 (adapter supplied with boiler)