Troubleshooting
3
Subject to modifications resulting from technical improvements!
Buderus Ltd. • http://www.buderus-domestic.co.uk
38
Servicing manual for wall-mounted condensing gas boiler 600 Series 11S/19S/24S/24C • Issued 02/2006
Fig. 35
Fault warning message 9C: Wiring to KIM connected incorrectly
Flashing
Incorrect cable connection at UBA,
or KIM defective
C
9
Yes
Connections OK?
No
Remove the casing (page 48)
Connect all terminals
correctly
"reset", Fit the casing
600 Series
11S / 19S / 24S / 24C
OK
Check cable connections at
KIM
Check wiring connection in UBA
A