background image

Page 1 

WARNING: If the information in this manual is not followed exactly, a fire or 
explosion may result causing property damage, personal injury or loss of life.

 

 

 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this 
or any other appliance. 

    
      WHAT TO DO IF YOU SMELL GAS 
 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use any phone in your building. 

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

instructions. 

 

If you cannot reach your gas supplier, call the fire department. 

 

 

Installation and service must be performed by a qualified installer, service agency or the 
gas supplier. 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is in-
stalled. Provisions for adequate combustion and ventilation air must be provided. Refer to 

section “ Producing Adequate Ventilation” page 14.

 

This appliance may be installed in an aftermarket, permanently located, manufactured 
(mobile) home, where not prohibited by local codes. 

 

This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases. 

INSTALLER: Leave this manual with the appliance. 
CONSUMER: Retain this manual for future reference.

 

MANUFACTURED BY  
NEW BUCK CORPORATION  

 

200 ETHAN ALLEN DRIVE,  

SPRUCE PINE, N.C.  28777                                  

 www.buckstove.com

                                                                                        

 

This appliance is intended for supplemental heating. 

 

This heater shall not be installed in a bedroom or 
bathroom.                                 

Revised January 2013

 

MODEL FP-327-ZC VENT-FREE GAS HEATER 

 

MAY BE INSTALLED AS A ZERO CLEARANCE FIREPLACE OR 

WITH AN OPTIONAL WOODEN SURROUND 

Содержание FP-327-ZC

Страница 1: ...It uses air oxygen from the room in which it is in stalled Provisions for adequate combustion and ventilation air must be provided Refer to section Producing Adequate Ventilation page 14 This applian...

Страница 2: ...Page 2...

Страница 3: ...te Air For Combustion And Ventilation 14 Ventilation Air For Combustion And Ventilation From Inside Building 16 Ventilation Air For Combustion And Ventilation From Outdoors 17 Gas Connection 18 Gas Pr...

Страница 4: ...National Fuel Gas Code ANSI Z223 1 NFPA54 2 This appliance may be installed in an After Market Manufactured Mobile Home where not prohibited by state or local codes After Market Completion of sale no...

Страница 5: ...equipped fresh air damper must be closed 12 Keep appliance area clean and free from combustible materials gasoline and other flammable flammable vapors and liquids 13 If burner shuts off do not religh...

Страница 6: ...tay away to avoid burns or clothing ignition 26 Young children should be carefully supervised when they are in the same room with the appliance 27 An unvented room heater having an input rating of mor...

Страница 7: ...er combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance SECTION II ZERO CLEARANCE INSTALLATION Th...

Страница 8: ...son The appliance should be inspected before use and at least annually by a professional ser vice person More frequent cleaning may be required due to excessive lint from carpeting bedding material et...

Страница 9: ...tetheinstallation steps in thesequenceshown LOCALBUILDING CODES SHOULD BE CONSULTEDINALL CASES AS TOTHEPARTICULAR REQUIREMENTSCONCERNINGTHE INSTALLATION OF FACTORY BUILT FIREPLACES Select thelocation...

Страница 10: ...board may not overlap the black face of the fireplace The space between the wall covering and the fireplace should be sealed with a heat resistant material such as rock wool insulation or mortar NOTE...

Страница 11: ...P TRIM METAL CEILING 2 2 2 42 COMBUSTIBLE MATERIAL NAILING FLANGE STAND OFF FP 327 ZC LOUVERS HOOD TOP TRIM METAL CEILING 2 6 2 2 42 MIN COMBUSTIBLE MATERIAL NAILING FLANGE STAND OFF FP 327 ZC LOUVERS...

Страница 12: ...THE APPLIANCE 2 Screen s can not be removed or altered Position screen s in the closed position before leaving heater unattended 3 Follow instructions for assembly of Optional Wooden Mantel See instru...

Страница 13: ...10 To light the heater see Lighting Instructions pages 21 through 28 Make sure you have the right gas valve for Natural or LP gas TOP MANTEL SIDE MANTEL 1 2 WOOD SCREWS 9 MANTEL BASE REAR OF HEATER F...

Страница 14: ...E HOME WHERE NOT PROHIBITED BY LOCAL CODES After Market Completion of sale not for the purpose of resale from the manufacturer THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATI...

Страница 15: ...ONAL FUEL GAS CODE ANSI Z223 1 NFPA 54 THE INTERNATIONAL FUEL GAS CODE OR APPLICABLE CODES WARNING IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE O...

Страница 16: ...nces Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU Hr the space can support with the actual amount of BTU Hr used ____________BTU Hr maximum th...

Страница 17: ...DING THE SPACE OF THE ADJOINING UNCONFINED SPACE THE COMBINED SPACES MUST HAVE ADEQUATE AMOUNT OF AIR TO SUPPLY ALL APPLIANCES IN BOTH SPACES NOTE Each opening shall have a minimum free area of 1 squa...

Страница 18: ...Air For Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet air into attic if attic has a thermostat controlled power vent Heated a...

Страница 19: ...right side for connection to the inlet of the valve NOTE The connecting pipe must be internally tinned copper tubing for use with natural gas Test for leaks using a solution of soap and water after co...

Страница 20: ...ial installation it may be necessary to bleed out air in the gas lines Do this by holding the control knob and turning the knob to the PILOT position for about 30 seconds To check the Regulator pressu...

Страница 21: ...PROVED WITH HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY WARNING DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE AVOID DRAFTS THAT ALTER BURNER FLAME PATTERN PLACEMENT OF LOGS Figure...

Страница 22: ...ry to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If...

Страница 23: ...off valve 8 Push the ON OFF toggle switch to OFF rocker switch 9 Turn gas control knob counterclockwise to the PILOT position Press in gas control knob for fifteen 15 seconds 10 With control knob pres...

Страница 24: ...mostat If so the Wall Thermostat needs to be set at a higher temperature than the room temperature TO TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT 1 Open access panel door located at bottom front of th...

Страница 25: ...e control knob counterclockwise to PILOT position Press in gas control knob for fifteen 15 seconds 4 Use rod to light match and ignite pilot The pilot is located in front of the rear log and burner on...

Страница 26: ...not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instruction...

Страница 27: ...the manual shut off valve 9 Turn control knob counterclockwise to the PILOT position Press in control knob for 15 fifteen seconds see figure 3 10 With control knob pressed in turn control knob clockw...

Страница 28: ...ositions as this can result in improper combustion and excessive carbon monoxide emissions PILOT PILOT BURNER IGNITER ELECTRODE THERMO COUPLE O D S 13 Close the access panel door 14 Turn on all electr...

Страница 29: ...to determine your personal comfort levels MANUAL LIGHTING PROCEDURE 1 If the pilot cannot be ignited with the igniter on the control valve it can be manually lit with the use of a paper match and a l...

Страница 30: ...the unit is in operation FLAME Propane LP should produce a flame that is 3 to 4 above rear log This flame should be yellow Natural gas should produce a flame that is 3 to 4 above rear log This flame s...

Страница 31: ...lower assembly is standard for this appliance and is installed by the manufacture Installation and repair should be done by a qualified service person This heater should be inspected before use and at...

Страница 32: ...G FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE NOTE PESBRO84 Blower Model FP 327 ZC Rating 120 volts 60HZ 0 54 Amps NOTE For...

Страница 33: ...LEANING OR MOVING THESE LOGS OR OTHER PARTS OF THE HEATER BE SURE TO READ THE ABOVE SECTIONS ON IMPORTANT SAFEGUARDS All cleaning should be carried out when the heater is cold Limited cleaning is requ...

Страница 34: ...cable 4 Igniter cable pinched or wet 5 Piezo igniter nut is loose 6 Broken igniter cable 7 Bad piezo igniter POSSIBLE CAUSE 1 Gas supply turned off or manual shutoff valve is closed 2 Control knob no...

Страница 35: ...g pilot flame to go out This problem can be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS Pilot 7 Control valve damaged 4 Continue to hold down control kno...

Страница 36: ...tion Gas odor during com bustion POSSIBLE CAUSE 1 Metal expands while heating or contracts while cooling 1 Heater burning vapors from paint hairspray glues etc See Important above 2 Low fuel supply 3...

Страница 37: ...d if equipped with this type of valve 2 Air in gas line 3 Air passageways on heater blocked 4 Dirty or partially clogged burner orifice SOLUTION 1 Clean burner see Cleaning and Maintenance or replace...

Страница 38: ...vice operation Check for gas leaks after servicing REPAIR PARTS A parts list with exploded view follows Always include correct name part number and model number of the heater when ordering service par...

Страница 39: ...er 1 6 PE TPT100 433 Thermo couple Copreci 1 7 PE 2150053 Copreci ODS Nat Pilot 1 7A PE 2150054 Copreci ODS LP Pilot 1 8 PE RV12LF30 Maxitrol Regulator Nat 1 8A PE RV12LF90 Maxitrol Regulator LP 1 9 R...

Страница 40: ...Page 38 BLOWN UP VIEW OF BURNER ASSEMBLY...

Страница 41: ...Maxitrol Regulator Nat 1 7A PE RV12LF90 Maxitrol Regulator LP 1 8 PE 124461 14 Igniter Wire 1 9 PE 4966 3 8 3 8 Elbow 1 10 PH 63212RPP 6 32X 1 2 Round Head Screw 4 11 PH 632HNP 6 32 Hex Nut 2 12 PE 64...

Страница 42: ...Page 40 BLOWN UP VIEW OF BURNER ASSEMBLY...

Страница 43: ...parts that are not in original condition normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installatio...

Страница 44: ...or warranty coverage to begin NAME ____________________________________________________ ADDRESS _________________________________________________ CITY _________________________________________________...

Отзывы: