Quick Start Guide
4
EC Declaration of Conformity
We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the
product
Dry Roof Pro2
is manufactured in conformity with the following directives:
2014/30/EU
,
2014/35/EU
and
2015/863/EU.
Date: 01/07/2021
Authorised by:
J P Hoveman
CEO, Buckleys (UVRAL) Ltd.
UKCA Declaration of Conformity
We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the
product
Dry Roof Pro2
is manufactured in conformity with the following UK legislation:
Electronic
Compatibility Regulations 2016
,
The Electrical Equipment (Safety) Regulations 2016
and
Restriction of the
Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
.
Date: 01/07/2021
Authorised by:
J P Hoveman
CEO, Buckleys (UVRAL) Ltd.
Specifications
Note:
Due to ongoing technical developments, all stated information is typical and is subject to change
without notice or obligation.
•
Output voltage range: 0.9kV – 40kV
•
Max. output current: <1mA (continuous)
•
Alarm sensitivity range: 10μA to 450μA
(factory-set to 200
μA)
•
Recommended coating thickness range:
13μm
– 25.6mm (using NACE SP0274)
•
Built-in test standard compliance: NACE
SP0274/ NACE SP0490/NACE SP0188/ASTM
D5172/ASTM G62/ISO 21809-2
†
•
Unit: 1.64kg, 172mm x 85mm x 235mm
•
Handle: 720g, 290mm x 85mm
Output voltage range:
•
Packed weight: 13.6kg
•
Dimensions (packed): 510 x 250 x 630mm
•
Battery type: 4 x D-cell/LR20
•
Meter accuracy: <10kV: +/- 10V. >=10kV +/-
100V
•
Current meter FSD:
450μA
•
Maximum relative humidity: 80% non-
condensing
•
Working altitude: <2000m
•
Temperature range: 0ºC - +40ºC
Model
Low Range
Increment
High Range
Increment
Polarity
Battery Life
Dry Roof Pro2
0.9kV-10kV
10V
10.1kV-40kV
100V
Positive
8 hours
* Test conducted in accordance with BS EN50356. Test units fitted with 10,000mAh NiMH rechargeable cells. Instrument output voltage set
to maximum.
† These standards are pre-programmed and are provided for convenience. However, it is the user’s responsibility to ensure that the
correct settings are chosen for the intended application of this unit.
Содержание DRY ROOF PRO2
Страница 8: ...Quick Start Guide 8 Setup...
Страница 10: ...Quick Start Guide 10 Basic Testing Press and hold the ON button 1m sec...
Страница 11: ...11 Basic Testing continued...