Buckleys DRY ROOF PRO2 Скачать руководство пользователя страница 4

Quick Start Guide 

4

 

EC Declaration of Conformity 

We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the 
product 

Dry Roof Pro2 

is manufactured in conformity with the following directives: 

2014/30/EU

2014/35/EU

 and 

2015/863/EU. 

Date: 01/07/2021

 

Authorised by: 

J P Hoveman 

CEO, Buckleys (UVRAL) Ltd.  

 

UKCA Declaration of Conformity 

We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the 
product 

Dry Roof Pro2 

is manufactured in conformity with the following UK legislation: 

Electronic 

Compatibility Regulations 2016

The Electrical Equipment (Safety) Regulations 2016 

and

 Restriction of the 

Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

Date: 01/07/2021

 

Authorised by: 

J P Hoveman 

CEO, Buckleys (UVRAL) Ltd.  

 

Specifications 

Note:

 Due to ongoing technical developments, all stated information is typical and is subject to change 

without notice or obligation. 

 

Output voltage range: 0.9kV – 40kV 

 

Max. output current: <1mA (continuous)

 

 

Alarm sensitivity range: 10μA to 450μA 

(factory-set to 200

μA)

 

 

Recommended coating thickness range: 

13μm 

– 25.6mm (using NACE SP0274)  

 

Built-in test standard compliance: NACE 

SP0274/ NACE SP0490/NACE SP0188/ASTM 

D5172/ASTM G62/ISO 21809-2

 

 

Unit: 1.64kg, 172mm x 85mm x 235mm 

 

Handle: 720g, 290mm x 85mm 

Output voltage range: 

 

Packed weight: 13.6kg 

 

Dimensions (packed): 510 x 250 x 630mm 

 

Battery type: 4 x D-cell/LR20 

 

Meter accuracy: <10kV: +/- 10V. >=10kV +/- 

100V    

 

Current meter FSD: 

450μA

 

 

Maximum relative humidity: 80% non-

condensing 

 

Working altitude: <2000m 

 

Temperature range: 0ºC - +40ºC 

 

Model 

Low Range 

Increment 

High Range 

Increment 

Polarity 

Battery Life 

Dry Roof Pro2 

0.9kV-10kV 

10V 

10.1kV-40kV 

100V 

Positive 

8 hours 

* Test conducted in accordance with BS EN50356. Test units fitted with 10,000mAh NiMH rechargeable cells. Instrument output voltage set 

to maximum. 

† These standards are pre-programmed and are provided for convenience. However, it is the user’s responsibility to ensure that the 

correct settings are chosen for the intended application of this unit. 

Содержание DRY ROOF PRO2

Страница 1: ...Electronic Flat Roof Leak Detection and Location Kit Quick Start Guide Please read this guide before using theequipment 5830 0047 11 21 English...

Страница 2: ...nings 3 EC Declaration of Conformity 4 UKCA Declaration of Conformity 4 Specifications 4 Maintenance 5 Register Your Product 5 Useful Advice 5 Kit Contents 6 Risk Assessment 7 Factory Settings 7 Setup...

Страница 3: ...eing immersed in water It must be immediately returned to Buckleys for service calibration and or repair A high voltage will always take the easiest route to earth The risk of electrical shock is inhe...

Страница 4: ...nge without notice or obligation Output voltage range 0 9kV 40kV Max output current 1mA continuous Alarm sensitivity range 10 A to 450 A factory set to 200 A Recommended coating thickness range 13 m 2...

Страница 5: ...mmediately To register your product simply visit www buckleysinternational com registration complete the online form and click on SUBMIT Useful Advice Instrument sensitivity Several variables includin...

Страница 6: ...5m earth cable on reel H D cell rechargeable batteries x4 I Battery charger with mains power adaptors and in car charger J Mid section extension rod x2 K End section extension rod L 450mm angled phosp...

Страница 7: ...materials been removed from the area to be tested EMC RFI Buckleys high voltage instruments will produce sparks which may create interference in nearby electronic apparatus particularly communication...

Страница 8: ...Quick Start Guide 8 Setup...

Страница 9: ...croll to Alarm Suppression and press b Press d or e until the display shows the desired number and press b Press c to return to the main display screen Refer to page 5 for more information on sensitiv...

Страница 10: ...Quick Start Guide 10 Basic Testing Press and hold the ON button 1m sec...

Страница 11: ...11 Basic Testing continued...

Страница 12: ...ish Contact Details Manufacturer Buckleys UVRAL Ltd Address Buckleys House Unit G Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG UK Tel 44 0 1303 278888 Email sales buckle...

Отзывы: