LRV-1 lift control valve
39/86
300-I-9010050-E-28/02.2012
Note:
In order to quit parameterisation mode:
S
Either press keys
↑
and
↓
simultaneously (changes to the currently
displayed parameter are saved)
or
S
unplug cable and wait for about 3seconds (changes to the
currently displayed parameter are NOT saved)
DELCON will return to RUN mode.
e.g.
K1-K8
1100
0000
C: +3.45
F: +4.18
Display during travel
S
1st line: status of command inputs K1…K8
0:
no command
1:
command is present
S
2nd line: existing control voltage (C) and
feedback value (F) in volts
e.g.
Fast speed
^
7.50V
Display during parameterisation
S
1st line: parameter name
S
2nd line: value of parameter, including unit
e.g.
1) Err:SIU-1
1x
51965h
Fault code
S
1st line: fault memory read-out, fault
description
S
2nd line:total number of occurrences of this
fault; last occurrence was at operating
hours h
S
For explanation of error codes
⇒
page78,
chapter5.7.2
3.5
Password
The DELCON's parameters and functions can be password-protected.
The password consists of four digits. Password “0000" means that
password protection is not activated (this is the factory setting).
Setting a password
1.
Press the key4
The display will read
Commands
Information list
.
2.
Press the key
↑
several times until the display reads
Password
+ execute
3.
Press the key+
Operating controls and indicators